Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 08-08-2015, 04:03 PM
e46er e46er is offline
Member
 
Join Date: Nov 2008
Location: Maple Ridge
Posts: 819
e46er is on a distinguished road
Default

Quote:
Originally Posted by clermont View Post
Hi everyone,

Like almost everyone in this hobby I would like to explore ways to improve my tank and wondering exactly how people are using their Reef Controllers and the benefits from using them.

I currently do not have one but everything I use seems to be pretty well automated on its own for example, Lights have built in timer, Power Heads have controller, 2 Heaters so if one stops working the other picks up the slack, ATO fuctions with float switches, and my feeder has a built in timer and I test the salinity of the tank fairly often but with a larger tank it seems to always be within range.
From what I have read the best benefit for me would be with the PH probe but to spend the amount of money required to pick up a reef keeper I am not sure the benefit is there.

I guess I could save a little money by having it turn on fans when the temperature reaches a certain point rather than running the fans all day?

Maybe, you all can give me some ideas for the uses and some input on more of the benefits I would see from using one.

Thanks for any input
I have a reefkeeperI also currently dont run an ATO.
I only have my skimmer, return pump and 2 heaters plugged into my controller.
powerheads and lights have their own controllers and the switch from MH to LED opened 3 additional outlets up so when I get around to it im going to use them to make WC and top off pumps run. not automatic but just so I hit a button and pump starts hit it again pump stops. with a ball valve that needs to be open first before it can go to the display. I just dont like the idea of cheep float swtiches connecting a 55gal drum of freshwater to my DT.

Now with so much equiptment have their own controllers (powerheads, DC pumps, LEDs, dosers ) I question whether a controller is necessary any more for me but I have it so Im going to continue to use it.
In my case Ill never run an ATO so all the float switches and alarms dont benifit me, no ca reactor so i havent checked my ph probe in years, house has central air so a chiller isnt required, so a $50 ranco heater a $10 digital thermometer controller and a couple of manual switched outlets so for roughly $75 I have almost the same thing 4-600 controller for how mine is used. but this is no where near the capibilities of the controller either.

A good controller is also almost endless in what you can do with it as well.
reduncy for auto top off
reduncy for heaters
stabile heat and cooling
automatic water changes
every safety feature you could possibly come up with.
time delays on outlets.
MH safety ( time delay start ups, lights off if tank reaches certain temp.)


they are a very nice piece of equiptment to have and a necessity if you run ATO chillers, MH lights, any non programmable light reallyjjust to ditch 3-5 manual timers, ca reactor, if you want an auto WC system.
__________________
250G DD LED SPS R.I.P.
180G LED SPS
80"x36". 300G custom build

Owner of Mountain Ridge Heating and Gas
Class A gas fitter, HVAC
Reply With Quote
  #2  
Old 08-08-2015, 06:44 PM
whatcaneyedo's Avatar
whatcaneyedo whatcaneyedo is offline
Member
 
Join Date: Apr 2007
Location: Prince George, BC
Posts: 2,198
whatcaneyedo is on a distinguished road
Send a message via MSN to whatcaneyedo
Default

Here is my response to the same basic question that was in a different thread a couple of months ago.

Quote:
Originally Posted by whatcaneyedo View Post
Full Apex here.
1. Turns the lights on and off according to a schedule and also if the tank gets too warm.
2. Shuts the return pump off if there is a flood or if the water level within the display tank raises too high.
3. Turns cooling fan and heater on and off as required to keep the temperature relatively steady.
4. With a couple float switches and a maxi-jet pump it is my ATO.
5. Turns a solenoid on and off twice a week to replenish the evaporation top off RO/DI water reservoir.
6. Controls the flow pattern of two Tunzes.
7. Turns a CO2 solenoid on and off to maintain a steady pH in the Calcium Reactor.
8. Turns the mixing pump on and off for the Kalkwasser Reactor several times a day.
9. Sounds an alarm or sends me a text/email if one of the pH readings isn't right, or if the tank is too warm, or if its flooding etc.
10. Allows me to shut anything off or turn anything on from an internet connection.
11. Enables me to shut the pumps or skimmer down for a few minutes during feeding or maintenance at the touch of a button, then starts those back up again automatically.

All this within one handy handy controller for a modest cost... as opposed to having 10 or more individual devices that are not cross integrated. On the downside I do have 'all of my eggs in one basket', but after 5(?) years of operation I have have only had one problem and it was my own fault for getting the module wet.
__________________
"We shall dive down through black abysses... and in that lair of the Deep Ones we shall dwell amidst wonder and glory forever." - H.P. Lovecraft

Old 120gal Tank Journal
New 225gal Tank Journal
May 2010 TOTM
The 10th Annual Prince George Reef Tank Tour
Reply With Quote
  #3  
Old 08-09-2015, 04:22 AM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by whatcaneyedo View Post
Here is my response to the same basic question that was in a different thread a couple of months ago.
__________________
Doug
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:07 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.