Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 02-14-2012, 01:14 AM
fishytime's Avatar
fishytime fishytime is offline
Member
 
Join Date: Mar 2007
Location: E-town
Posts: 5,390
fishytime will become famous soon enough
Default

Quote:
Originally Posted by gregzz4 View Post
The Herbie works just fine for most, and is what I am setting up on my Aqueon 75g RR, but, the emergency line on a Herbie has to purge itself of air before it can flow full volume. For most of us, that is on the edge of flood as most of our emerg lines are high and small.
All the Bean does is place the secondary at the same height of the main, so it's less prone to floods. Then you still have an emerg
how?.....you stop the emergency just short of your water line in the sump so you can hear if the primary is clogged or needs adjusting....straight open run means no purging......
__________________
260g mixed reef, 105g sump, water blaster 7000 return, Bubble King SM 300 skimmer, Aqua Controller Jr, 4 radions, 3 Tunze 6055s,1 tunze 6065, 2 Vortech MP40s, Vortech MP20, Tunze ATO, GHL SA2 doser, 2 TLF reactors (1 carbon, 1 rowa). http://www.canreef.com/vbulletin/showthread.php?t=50034 . Tank Video here http://www.vimeo.com/2304609 and here http://www.vimeo.com/16591694

Last edited by fishytime; 02-14-2012 at 01:16 AM.
Reply With Quote
  #2  
Old 02-14-2012, 02:21 AM
Daimyo68 Daimyo68 is offline
Junior Member
 
Join Date: Feb 2012
Location: Florida
Posts: 8
Daimyo68 is on a distinguished road
Default

Below is my 50g with the BA drain system. As some have mentioned here and BeanAnimal has in his threads, Horizontal is not how his system is meant to run. Vertically is the best way to make his system run optimally. There are no bends/elbows for the water to hit, causing friction, hence slowing down. Unfortunately, this isn't always possible, as you will see below.

In the first image from left to right- Secondary drain | Siphon Drain | Emergency

I have a slight horizontal run, about 4", before it 45's down to the sump. I tried to avoid this but the way the Oceanic stand is built with the center brace, I couldn't. While this isn't the way the system is designed, it does work and is quite.

If you have to go horizontal at all, it's best to make it as short as possible.

On my 75g image (SPS tank in the works), the Siphon line isn't completely vertical, but it still lets gravity do it's job. I could have drilled at the upper back corner for all 3 drains, but I didn't want my mini C2C to be offset to one side, and opted to drill at the upper center, just under the brace.

In all honesty, the "reef ready", Herbie and BeanAnimal all work with the same thing in mind, drain the water to the sump. The BeanAnimal has the advantage of a failsafe channel and +3000gph through 1.5" plumbing on a completely vertical system. I'm sure that a Herbie through 1.5" could probably do the same, if not close to gph.

When it comes down to it, do we all really need the BA system? The answer is no. I really think it's more of a "reef geek" thing. Just like PC lighting, to HO, to Halides, to T5HO, and now LED's, it's the latest/greatest thing since sliced bread



Reply With Quote
  #3  
Old 02-14-2012, 05:26 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Daimyo68 View Post
Below is my 50g with the BA drain system. As some have mentioned here and BeanAnimal has in his threads, Horizontal is not how his system is meant to run. Vertically is the best way to make his system run optimally. There are no bends/elbows for the water to hit, causing friction, hence slowing down. Unfortunately, this isn't always possible, as you will see below.

In the first image from left to right- Secondary drain | Siphon Drain | Emergency

I have a slight horizontal run, about 4", before it 45's down to the sump. I tried to avoid this but the way the Oceanic stand is built with the center brace, I couldn't. While this isn't the way the system is designed, it does work and is quite.

If you have to go horizontal at all, it's best to make it as short as possible.

On my 75g image (SPS tank in the works), the Siphon line isn't completely vertical, but it still lets gravity do it's job. I could have drilled at the upper back corner for all 3 drains, but I didn't want my mini C2C to be offset to one side, and opted to drill at the upper center, just under the brace.

In all honesty, the "reef ready", Herbie and BeanAnimal all work with the same thing in mind, drain the water to the sump. The BeanAnimal has the advantage of a failsafe channel and +3000gph through 1.5" plumbing on a completely vertical system. I'm sure that a Herbie through 1.5" could probably do the same, if not close to gph.

When it comes down to it, do we all really need the BA system? The answer is no. I really think it's more of a "reef geek" thing. Just like PC lighting, to HO, to Halides, to T5HO, and now LED's, it's the latest/greatest thing since sliced bread
Thanks for the pic and image.
Thought you should edit your post to not mislead others ...


From left to right, based on your valve in the center, you have yours setup as;
  • Emergency Standpipe
  • Full Siphon Standpipe
  • Open Channel Standpipe
You have worded your Emerg and Open reversed.

Last edited by gregzz4; 02-14-2012 at 05:28 AM.
Reply With Quote
  #4  
Old 02-14-2012, 05:55 AM
braid11 braid11 is offline
Member
 
Join Date: Nov 2005
Location: Whistler/North Shore BC
Posts: 31
braid11 is on a distinguished road
Default

So, I made it home tonight.

I lifted the drains out of the sump so they were just 1/2- 1 " into the sump water level, and restarted the system. It purged the air much quicker. Level in DT did not rise above the overflow box level. No where close to an overflow, at close to 1000 GPH.

Now it's tough getting the level and noise in the DT overflow to stabalize/quiet down. The main syphon seems noisy, like air is trapped in the overflow section Tee.

It must be a residual air purge issue.

Tom
Reply With Quote
  #5  
Old 02-14-2012, 05:58 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

If I understand correctly, Bean runs his drain 2" below his sump level
Have you looked @ his page?
http://www.beananimal.com/projects/s...w-system.aspx/
Reply With Quote
  #6  
Old 02-14-2012, 06:00 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

NM, I just skimmed it and it only states 'just below the water level' or such.
I read somewhere that people are running theirs @ 2" with success. It helps draw the water down as there is no air in the lines. If your's is better now, leave it be.
Good luck with the overflow, you'll figure it out.
Reply With Quote
  #7  
Old 02-14-2012, 12:33 PM
Daimyo68 Daimyo68 is offline
Junior Member
 
Join Date: Feb 2012
Location: Florida
Posts: 8
Daimyo68 is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post
Thanks for the pic and image.
Thought you should edit your post to not mislead others ...


From left to right, based on your valve in the center, you have yours setup as;
  • Emergency Standpipe
  • Full Siphon Standpipe
  • Open Channel Standpipe
You have worded your Emerg and Open reversed.
Thanks, I guess seeing it from the front all them time I unconsciously just labeled them while I typed it out.
Reply With Quote
  #8  
Old 02-14-2012, 07:59 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Daimyo68 View Post
Thanks, I guess seeing it from the front all them time I unconsciously just labeled them while I typed it out.
Of course, I should have thought of that myself
Don't want anyone new to this getting confused
Reply With Quote
  #9  
Old 02-14-2012, 05:13 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by fishytime View Post
how?.....you stop the emergency just short of your water line in the sump so you can hear if the primary is clogged or needs adjusting....straight open run means no purging......
Not sure what your 'how' is referencing, but, here goes ...
You can't hear it from work
Remember, I'm setting up a Herbie, so don't pick on me.
I'm just stating what I've learned about the Bean.
It's self-adjusting and virtually flood-proof. The Herbie is very close to this, but is NOT flood-proof.
Reply With Quote
  #10  
Old 02-14-2012, 05:16 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Oh, and for the purging ...
A Herbie takes time to get the emerg going as it has air in it, from the venturi caused by it being high/tall whatever.
The secondary on the Bean is capable of blocking it's air intake when the overflow level rises.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:19 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.