Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 12-31-2011, 05:34 PM
Maverick00 Maverick00 is offline
Member
 
Join Date: Mar 2010
Location: Vancouver Island
Posts: 380
Maverick00 is on a distinguished road
Default

My charcoal and prefilter are clear housings as well @90psi. I assumed this pressure would be alright (even though its higher than the reccomended) because the booster pump does not have any sort of adjustable pressure regulator which i actually found alittle strange when i hooked it all up. Is it standard practice to install a pressure regulator after the booster pump to maintain a lower pressure than what the booster is providing? Feels like im chasing my tail on this one.
__________________

- 33 Gal - 20Gal Sump, MP10/Hydor Powerheads, Aquaticlife 4x T-5HO, Vertex IN100, TLF w/Biopellets, Tunze ATO

-45GAL Build in Progress!-
Reply With Quote
  #2  
Old 12-31-2011, 08:11 PM
Buckeye Field Supply Buckeye Field Supply is offline
Junior Member
 
Join Date: Nov 2011
Location: Ohio
Posts: 20
Buckeye Field Supply is on a distinguished road
Default

If you buy the right brand of pump (Aquatec), the adjustable pressure comes built in. On the cheaper brands it doesn't.

Russ
Reply With Quote
  #3  
Old 12-31-2011, 10:54 PM
mike31154's Avatar
mike31154 mike31154 is offline
Member
 
Join Date: Jul 2008
Location: Vernon
Posts: 2,073
mike31154 will become famous soon enough
Default

Quote:
Originally Posted by Maverick00 View Post
My charcoal and prefilter are clear housings as well @90psi. I assumed this pressure would be alright (even though its higher than the reccomended) because the booster pump does not have any sort of adjustable pressure regulator which i actually found alittle strange when i hooked it all up. Is it standard practice to install a pressure regulator after the booster pump to maintain a lower pressure than what the booster is providing? Feels like im chasing my tail on this one.
The PRV I was referring to in my post is in my home plumbing, I do not have a booster pump. City pressure to my house is generally between 110 & 120 psi. My residential tax dollars at work, there be some hills to pump the water up around here, so the City of Vernon doesn't mess around. They upgraded the water pumps to some big a$$ units a couple of years ago. The PRV is about 15 feet downstream of my main water shutoff & meter. My east outdoor spigot for the garden & irrigation system gets full city pressure, which is handy. Pretty sure the local plumbing code requires every home to have one of these now to get the pressure down to or below the standard 80psi that Russ from BFS quotes. I've got the adjustment screw on my PRV cranked pretty good, in fact I've observed close to 100 psi into my RODI recently! So far so good, but Russ mentioning caution with the clear housings causes me some concern, this is why I asked for more info on that. I think I'll do some net searching on the subject & see what I come up with.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:55 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.