Quote:
Originally Posted by fishytime View Post
ATO to RO is a disaster waiting to happen.....never plumb an ATO to an unending water source, or a reservoir big enough to cause a drastic salinity swing......RO membranes function best when they have water running through them for more than just a few seconds.....short run times, like when you have it plumbed to an ATO will shorten the lifespan on the membrane....
Agree with ya there Doug on the life span. but my water is 980 coming out so i might as well have some happiness withthe RO DI line

as for the RO line running the Kalk reactor when the water goes in it only goes in at the speed as the small union is screw into so If I want 3 drips per second coming out. Then 3 drips per second will only go in.
__________________
180 starfire front, LPS, millipora
Doesn't matter how much you have been reading until you take the plunge.
You don't know as much as you think.
Reply With Quote
  #2  
Old 12-07-2011, 06:53 AM
martinmcnally martinmcnally is offline
Member
 
Join Date: Jul 2008
Location: Red Deer
Posts: 603
martinmcnally is on a distinguished road
Default

I used to have a Tunze. Pump would burn out every few months to the point where I was buying 3 at a time. Then the unit died one day

Ordered a kit from this guy: http://autotopoff.com/

I got the solenoid version so I have it plumbed directly into my filter. Never had a problem or hickup since. That was about a 2 years ago now.
__________________
Western Database - Custom database, software design and cloud hosting.
Reply With Quote
  #3  
Old 12-07-2011, 11:00 AM
Douglas Douglas is offline
Member
 
Join Date: Nov 2007
Location: Calgary
Posts: 251
Douglas is on a distinguished road
Default

I use this system, with an aqua lifter, in my tank/sump. it hasn't failed me yet. Just another option. And is cheaper.

http://www.aquariumsupplies.ca/tsuna...tem-p-840.html

Last edited by Douglas; 12-07-2011 at 11:03 AM.
Reply With Quote
  #4  
Old 12-07-2011, 01:56 PM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

go the mechanical float valve (for furnace humidifier from HD, $12) connected directly to RO/DI. 6 years, zero problems, can't say I notice TDS creep, only second membrane since started (and believe probably changed out first when didn't have to), simple.

Yes there's a risk but the valve is continuously being flushed with fresh water and really this is the same valve used on furnaces. Figure there's a whole bunch more furnaces than fish tanks and can't ever say I've heard of someone flooding their basement because the humidifier screwed up.

__________________
my tank

Last edited by mark; 12-07-2011 at 02:00 PM. Reason: added picture
Reply With Quote
  #5  
Old 12-07-2011, 02:37 PM
lastlight's Avatar
lastlight lastlight is offline
Gold Member
 
Join Date: Jan 2006
Location: Calgary
Posts: 6,997
lastlight has a spectacular aura aboutlastlight has a spectacular aura aboutlastlight has a spectacular aura about
Default

Just got my osmolator back online last night topping up the new tank. Dumping several gallons by hand everyday wasn't difficult but man I love the convenience of my Tunze! The pump is going to be on much longer each time so I'll have to see what that means in terms of its lifespan.

Quote:
Originally Posted by mark View Post
the valve is continuously being flushed with fresh water
Not to mention the furnace version would be flushed with regular water so there could be buildups. I still am not a fan of this method though.
__________________
Brett
My 67 392 225 101 94 34 97 404 28 93 209 gallon reef.
Reply With Quote
  #6  
Old 12-07-2011, 03:01 PM
pscott99's Avatar
pscott99 pscott99 is offline
Member
 
Join Date: Dec 2010
Location: Stratford ON
Posts: 58
pscott99 is on a distinguished road
Default

Mark how did you mount the HD float. I am looking at that today also. As long as you don't have too large of a supply bucket this will work fine for my tank. I do have one on my furnace. If I was running a 30gal bucket I wouldn't take the chance. I am actually using a simple gravity feed with a loop tied in the pvc and even that works fine. The float will give a little better control.
__________________
28gal reef tank
nov 2010
Reply With Quote
  #7  
Old 12-07-2011, 08:36 PM
TimT's Avatar
TimT TimT is offline
Member
 
Join Date: Nov 2001
Location: Courtenay, BC
Posts: 600
TimT is on a distinguished road
Default

I use a Little Giant livestock waterer with an acrylic rod mod and nylon bolts/nuts to attach it. Plumbed via a 1/4" shut off valve(to reduce flow) to my 75gpd ro membrane with auto shut off valve. 0 failures in 12 years. 3 membranes in 12 years too.

If you can't do it that way then I would recommend the Tunze. I stay away from American labeled off shore crap whenever possible.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies