Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 09-21-2011, 10:55 PM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

Looks great!, the idea for larger holes is good, the larger the hole the less velocity the water will have getting sucked in, meaning it sucks in the least amount of "unwanted" stuff. And also, I've never heard of people saying they have too big of holes drilled in the tank, can always adapt down, can't open them up (easily). Definitely have ball valves and unions on both sides of the motor. Rarely needs to be serviced, but it'll be night and day how things go when you have them.( I don't, it sucks).

I have the exact same setup for a sump, the only thing i would add is a better way to hold filter socks in on the skimmer side. I don't always run them, but they are kinda jammed in there when i do. The other thing is possibly adding a 4th weir to the skimmer side(i imagine will have more flow?), or keep the ATO at the level you have in the pic, which is probably a better idea . My 1" waterfall from the skimmer weir into the return section causes lots of micro bubbles.

I like the dimensions for the display, little more shallow and wide than most, will make a great reef.
__________________
My 150 In Wall Build
Reply With Quote
  #2  
Old 09-21-2011, 11:05 PM
Myka's Avatar
Myka Myka is offline
Moderator
 
Join Date: Mar 2004
Location: Saskatoon, SK.
Posts: 11,268
Myka will become famous soon enough
Default

I didn't even look at your sump design...what are you using the fuge for? Pods or macroalgae culture? I also suggest you do your baffles the other way - first and last one raised up, middle one on the bottom. The baffles don't have to be that tall either. If the water level is 8" make the baffles 10" or so.

Quote:
Originally Posted by Lampshade View Post
Definitely have ball valves and unions on both sides of the motor.
Dood, use true union ball valves. Union and ball valve in one. Takes up less space and costs a tad less.
__________________
~ Mindy

SPS fanatic.


Last edited by Myka; 09-21-2011 at 11:08 PM.
Reply With Quote
  #3  
Old 09-22-2011, 12:01 AM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

Quote:
Dood, use true union ball valves. Union and ball valve in one. Takes up less space and costs a tad less.
:O Magic! I didn't even know those existed. Thanks , i know what i'm doing for the next one.
__________________
My 150 In Wall Build
Reply With Quote
  #4  
Old 09-22-2011, 01:55 AM
Starry Starry is offline
Member
 
Join Date: Dec 2005
Location: Lethbridge, AB
Posts: 619
Starry is on a distinguished road
Default

k, will do up some new diagrams tonight or tomorrow. The fuge is for both pods and macros...they kinda go together. Where can I find these union valves?...

Mindy, why reverse the baffles? wouldnt that suck any sand or anything outta the fuge area?
__________________
Starry
180 custom starfire
http://s1083.photobucket.com/albums/...0%20july%2007/
Reply With Quote
  #5  
Old 09-22-2011, 02:22 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

remember true union valves come apart so install in the right direction
__________________
my tank
Reply With Quote
  #6  
Old 09-22-2011, 02:52 AM
Starry Starry is offline
Member
 
Join Date: Dec 2005
Location: Lethbridge, AB
Posts: 619
Starry is on a distinguished road
Default

Any one have a diagram on how to plumb a om 4 way so i have 4 outlets in front and 2 behind the rock work? also, aside from the price, whats the difference between a super squirt and a 4 way?
__________________
Starry
180 custom starfire
http://s1083.photobucket.com/albums/...0%20july%2007/
Reply With Quote
  #7  
Old 09-22-2011, 04:21 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

difference between squirt and 4way is the flow they can handle. Check OM Waterpix forum for CL layout ideas.
__________________
my tank
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:02 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.