Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > DIY

Reply
 
Thread Tools Display Modes
  #1  
Old 02-11-2010, 05:44 PM
hillegom hillegom is offline
Member
 
Join Date: Nov 2008
Location: Surrey
Posts: 1,998
hillegom is on a distinguished road
Default

You do not have to have a tank in your RO system to have an auto shut off valve (ASOV)
Most systems come with this valve so that the unit shuts itself off and does not make any more ro water nor any more water to the drain.
Here is a link, for a picture, there are a lot of pics on the web.
http://www.goodwaterwarehouse.com/cat/6_roasv.shtml
Reply With Quote
  #2  
Old 02-11-2010, 05:56 PM
superduperwesman's Avatar
superduperwesman superduperwesman is offline
Member
 
Join Date: Sep 2007
Location: Calgary
Posts: 850
superduperwesman is on a distinguished road
Default

Quote:
Originally Posted by hillegom View Post
You do not have to have a tank in your RO system to have an auto shut off valve (ASOV)
Most systems come with this valve so that the unit shuts itself off and does not make any more ro water nor any more water to the drain.
Here is a link, for a picture, there are a lot of pics on the web.
http://www.goodwaterwarehouse.com/cat/6_roasv.shtml
Oh ok... thanks. I'll look for this when I get home... like I said. I don't actually have it all plumbed in yet I was just trying the float valve out on the R/O supply line that I ran. I'm gonna pick up my R/O from my old place this weekend.
Reply With Quote
  #3  
Old 02-11-2010, 06:08 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by banditpowdercoat View Post
what does not make sence? I think I'm being clear? I made last post before I seen his last ones
Most of it, but don't take it personally. All RO units should have an auto shut off unless they are the portable units which are only hocked up to a water source when needed. I wouldn't say that's the norm most units are permanently hooked up to a water source and the shut off valve is on the output. This being the case it will require an auto shut off whether a pressure storage tank is used or not.

The basic rule is to never rely on mechanical floats. I believe humidifiers have a drain if the water level gets too high, same as a toilet. Electronic systems can be designed with unlimited safety systems to prevent failure so you actually design them to meet your own personal confidence level.

Last edited by sphelps; 02-11-2010 at 06:12 PM.
Reply With Quote
  #4  
Old 02-11-2010, 06:41 PM
viperfish's Avatar
viperfish viperfish is offline
Member
 
Join Date: Aug 2009
Location: Dawson Creek
Posts: 684
viperfish is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
The basic rule is to never rely on mechanical floats. I believe humidifiers have a drain if the water level gets too high, same as a toilet.
Most older humidifiers have a float valve and pan to hold water, the only drain is the one on the floor when it overflows. The mechanical float valves on these units last for years without fail. In my previous house the float valve had been working for 11 years and had not spilled a drop. The key to these things is simplicity. In my current humidifier I have an electronic solenoid and it took three of them before I got one that worked properly. I don't know of too many electronic devices, especially ones controlling water, that I would trust for 10+ years.
Reply With Quote
  #5  
Old 02-11-2010, 06:42 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Well, I have just seen more of the temp hookup style RO units in this hobby than the permanent, drinking water kind.
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
  #6  
Old 02-11-2010, 04:52 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Quote:
Originally Posted by superduperwesman View Post
Yeah, I won't 100% trust in which is why I have the valve as an extra precaution.

But again, I'm not really understanding the RO Auto shut-off?

Once the little R/O pressure tank fills doesn't the unit always shut off?
Ohh you have a RO unit with the pressure tank, then you should allready have a shut off valve. basic RO/DI units like most reefers have do not have the shutoff incorporated as they do not have a pressure tank.

This is what I am refering to
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
Reply


Posting Rules
You may not post new threads