Looks good. But, I wouldnt rule out the possibility of having to go to even smaller nozzles. Basically, to pressurize the loop a bit, the are of all the nozzles will have to add up to less than the area of the feed pipe. You might even get good results going to 3/4" outlets?? Freshwater test will tell you, and as long as you dont cement the nozzles in, which I wouldnt anyways for cleaning purposes, you can adapt down to smaller real easily. I'd fill tank to just below nozzles and try it, if your drain/overflow will allow that. That way you can see the water coming from each pipe easily.
Reply With Quote
  #2  
Old 11-09-2007, 01:55 AM
GreenSpottedPuffer's Avatar
GreenSpottedPuffer GreenSpottedPuffer is offline
Member
 
Join Date: Jan 2007
Location: Vancouver
Posts: 2,337
GreenSpottedPuffer is an unknown quantity at this point
Default

Quote:
Originally Posted by banditpowdercoat View Post
Looks good. But, I wouldnt rule out the possibility of having to go to even smaller nozzles. Basically, to pressurize the loop a bit, the are of all the nozzles will have to add up to less than the area of the feed pipe. You might even get good results going to 3/4" outlets?? Freshwater test will tell you, and as long as you dont cement the nozzles in, which I wouldnt anyways for cleaning purposes, you can adapt down to smaller real easily. I'd fill tank to just below nozzles and try it, if your drain/overflow will allow that. That way you can see the water coming from each pipe easily.
Yeah I can probably fill it a bit lower for the test. Im not so sure about anything lower than 1.5" nozzles though. I really don't want to reduce from 2" to something like 3/4" or I may as well have used a much smaller pump too. I think this pump at 6000 GPH can give good flow to all the outlets even at 1.5". I could be wrong though.

The nozzles will not be cemented in either because I do not want them stuck in one place. The tank is so shallow that Im sure this will give more than enough flow to the whole thing and then some.
Reply With Quote
  #3  
Old 11-09-2007, 02:09 AM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Ahh yes, 6000GPH Somehow I missed that. I will be interested to see how she works Just got my top loop for the 45g done tonight. Most of the other plumbing done as well. Just need to find a reasonably priced 36" tank for my Freshwater fish, so I can steal their present tank for the sump LOL
Reply With Quote
  #4  
Old 11-09-2007, 02:35 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

It looks GREAT.

Like how you got the 45° set up, you're making your own Omni Flex nozzles

Close the loop to more evenly balance flow from all outlets (reference here). And you know the manifold has to be good, Holmes on Holmes pushes the manifold for houses)

Get so water in there and try it out.

Last edited by mark; 11-09-2007 at 02:41 AM.
Reply With Quote
  #5  
Old 11-09-2007, 03:04 AM
GreenSpottedPuffer's Avatar
GreenSpottedPuffer GreenSpottedPuffer is offline
Member
 
Join Date: Jan 2007
Location: Vancouver
Posts: 2,337
GreenSpottedPuffer is an unknown quantity at this point
Default

Quote:
Originally Posted by mark View Post
It looks GREAT.

Like how you got the 45° set up, you're making your own Omni Flex nozzles

Close the loop to more evenly balance flow from all outlets (reference here). And you know the manifold has to be good, Holmes on Holmes pushes the manifold for houses)

Get so water in there and try it out.

Oh yeah its going to be all closed for sure. I had thought about doing half of one type thing but realized it would never work as well. I am going to cement the actually manifold tonight except of course all the outlets. I hope I can keep the outlets "uncemented", even the black reducers you see in the pics but I thought the pressure might be a bit much and eventually pop out the reducers. I guess cementing them in is ok but I like to have the option of changing still if I want.
Reply With Quote
  #6  
Old 11-09-2007, 03:01 AM
GreenSpottedPuffer's Avatar
GreenSpottedPuffer GreenSpottedPuffer is offline
Member
 
Join Date: Jan 2007
Location: Vancouver
Posts: 2,337
GreenSpottedPuffer is an unknown quantity at this point
Default

Quote:
Originally Posted by banditpowdercoat View Post
Ahh yes, 6000GPH Somehow I missed that. I will be interested to see how she works Just got my top loop for the 45g done tonight. Most of the other plumbing done as well. Just need to find a reasonably priced 36" tank for my Freshwater fish, so I can steal their present tank for the sump LOL
Yeah your closed loop looked great! When do you figure you can have it all going by? If your like me, your getting really impatient! Well honestly, my fish are the ones getting really impatient...
Reply With Quote
  #7  
Old 11-09-2007, 03:38 AM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Quote:
Originally Posted by GreenSpottedPuffer View Post
Yeah your closed loop looked great! When do you figure you can have it all going by? If your like me, your getting really impatient! Well honestly, my fish are the ones getting really impatient...
Well, I'm hopin to have water by end of the month, better be sooner HAHAHA. We just re arranged the living room tonigth, put the tank in another corner. And then I did the smart thing and checked my finances....I'll be over in the corner here sobbing uncontrollably LMAO
Reply With Quote
  #8  
Old 11-09-2007, 03:53 AM
GreenSpottedPuffer's Avatar
GreenSpottedPuffer GreenSpottedPuffer is offline
Member
 
Join Date: Jan 2007
Location: Vancouver
Posts: 2,337
GreenSpottedPuffer is an unknown quantity at this point
Default

Quote:
Originally Posted by banditpowdercoat View Post
Well, I'm hopin to have water by end of the month, better be sooner HAHAHA. We just re arranged the living room tonigth, put the tank in another corner. And then I did the smart thing and checked my finances....I'll be over in the corner here sobbing uncontrollably LMAO
I hear you about the finances! I can not really change or add much for a good long while now. Even going today to get the ABS stuff for the outlets ended up being like $50...not so bad BUT when you add up all the $50 trips, it gets a little crazy. Well over $2000 now. Im pretty excited to get some fresh water in it saturday and then if all goes well, drain it and start adding RO water maybe Monday or Tuesday. I want to get the LR in the tank by next Tuesday or Wednesday and see if there is a bit of a cycle which I expect. We will see though if that all goes as planned. Nothing really has so far!
Reply With Quote
  #9  
Old 11-09-2007, 03:57 AM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

LOL, Ya I just spent $67 on more fittings tonight too, My 3rd trip for PVC, and I think I'll have one more. Alot of stuff for a 45g, dang LOL. But, I am serious on wanting this tank, so I aint givin up
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:46 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.