this only happens after a water damage:
...
this only happens after a water damage:
either the front board (mostly the buttons) got wet or the small board inside with the western sockets got wet
in some cases it helps to clean the...
|
Forum: Controller and Monitoring Specific
07-27-2012, 08:18 AM
|
Replies: 79
Views: 21,155
yes, we will help him, I just need a message...
yes, we will help him, I just need a message (maybe he needs a Mitras or something else)
you must know that nobody from our company was in direct touch with him
I assume the communication...
|
Forum: Controller and Monitoring Specific
07-27-2012, 07:38 AM
|
Replies: 79
Views: 21,155
|
Forum: Controller and Monitoring Specific
07-27-2012, 07:30 AM
|
Replies: 79
Views: 21,155
|
Forum: Controller and Monitoring Specific
07-27-2012, 07:00 AM
|
Replies: 79
Views: 21,155
I think we have to correct this also
...
I think we have to correct this also
complete nonsense - why should float sensors expire? My float-sensors had been working now for 6 years without a problem.
Who tells these stories?...
|
Forum: Controller and Monitoring Specific
07-27-2012, 06:47 AM
|
Replies: 79
Views: 21,155
Hello,
I am the owner of GHL/ProfiLux and...
Hello,
I am the owner of GHL/ProfiLux and the main developer of the firmware, I've been working on the firmware now for about 14 years. I think I now every bit and byte of the firmware.
A few...
|
Forum: GHL Profilux Info & Support
06-29-2008, 08:56 AM
|
Replies: 145
Views: 31,448
|
Forum: GHL Profilux Info & Support
06-26-2008, 03:30 PM
|
Replies: 145
Views: 31,448
|
Forum: Product Review and Equipment Forum
03-15-2008, 01:10 PM
|
Replies: 22
Views: 3,308
|
Forum: Product Review and Equipment Forum
02-22-2008, 10:43 AM
|
Replies: 714
Views: 132,163
New software 4 for ProfiLux
Hi
the new ProfiLuxControl II V4.0.0.3 BETA and the new firmware V4.00 BETA for ProfiLux is available for download:
...
|
Forum: Product Review and Equipment Forum
01-15-2008, 06:09 AM
|
Replies: 714
Views: 132,163
enter the values in "mode", "duration" and...
enter the values in "mode", "duration" and "waves" of the first pump group
the 1-10V-settings have to be done under "extras -> 1-10V-interfaces".
I recommend to set the voltages to Min = 3V and...
|
Forum: Product Review and Equipment Forum
01-08-2008, 06:14 AM
|
Replies: 714
Views: 132,163
@egareef:
in 3.07 we reprogrammed the...
@egareef:
in 3.07 we reprogrammed the calculation conductivity <-> salinity <-> density (we made it more precisely with more digits behind the decimal point) and we changed the displayed texts...
|
Forum: Product Review and Equipment Forum
12-14-2007, 06:52 AM
|
Replies: 714
Views: 132,163
|
Forum: Product Review and Equipment Forum
12-09-2007, 08:48 AM
|
Replies: 714
Views: 132,163
Hi
in dosing mode the start time can't be...
Hi
in dosing mode the start time can't be changed, the times are calculated automatically. If you want to dose at specific times you have to use a timer instead of the dosing function.
|
Forum: Product Review and Equipment Forum
12-04-2007, 06:27 AM
|
Replies: 714
Views: 132,163
Hi,
you can do this if you want. But: Please...
Hi,
you can do this if you want. But: Please make sure that it's exactly the same type (8A, 125V, time-lag, UL/UR or CSA certificated!).
And we made once the experience that there are fuses...
|
Forum: Product Review and Equipment Forum
12-03-2007, 06:58 AM
|
Replies: 714
Views: 132,163
|
Forum: Product Review and Equipment Forum
11-30-2007, 06:57 AM
|
Replies: 714
Views: 132,163
There are fuses in the powerbars with inrush...
There are fuses in the powerbars with inrush current protection.
Maybe this fuse is blown - replace it with exactly this type.
For a test you can simply use a fuse from another socket. Please refer...
|
Forum: Product Review and Equipment Forum
11-29-2007, 07:02 AM
|
Replies: 714
Views: 132,163
You can control up to 8 dimmable lights...
You can control up to 8 dimmable lights independently. Of course more than 8 lights can be controlled (dimmed) but then some of them have to be controlled simultanously (groups of lights).
For your...
|
Forum: Product Review and Equipment Forum
11-24-2007, 10:49 AM
|
Replies: 714
Views: 132,163
|
Forum: Product Review and Equipment Forum
11-18-2007, 10:00 AM
|
Replies: 714
Views: 132,163
not correct
you have to adjust the...
not correct
you have to adjust the "rate/dosing".
The flow rate describes the used pump. Maybe something between 55 and 65ml.
In your case 1ml. If "dosings per day" = 24 you dose 24ml per...
|
Forum: Product Review and Equipment Forum
11-18-2007, 08:22 AM
|
Replies: 714
Views: 132,163
@reef:
The dosing pumps have a flow rate of...
@reef:
The dosing pumps have a flow rate of approx. 60ml/min. Due to tolerances of the motor or the pump it is possible that a pump has a different flow rate. You can correct the parameter...
|
Forum: Product Review and Equipment Forum
11-17-2007, 02:48 PM
|
Replies: 714
Views: 132,163
|
Forum: Product Review and Equipment Forum
11-17-2007, 07:07 AM
|
Replies: 714
Views: 132,163
|
Forum: Product Review and Equipment Forum
11-17-2007, 05:33 AM
|
Replies: 714
Views: 132,163
reef,
regarding dosing pump.
Your pumps...
reef,
regarding dosing pump.
Your pumps have numbers 1,2,3,4, correct?
And your powerbar has some numbers above, for example 5-10?
If you use the manual override can you activate each...
|