#681
|
||||
|
||||
![]() please contact Aqua Digital for a original fuse from GHL
|
#682
|
|||||
|
|||||
![]() Thanks
Is there any reason I couldn't just go to an electronics store like radio shack or something and get an 8 amp fuse from them? |
#683
|
||||
|
||||
![]() Hi,
you can do this if you want. But: Please make sure that it's exactly the same type (8A, 125V, time-lag, UL/UR or CSA certificated!). And we made once the experience that there are fuses available which become very hot. Our fuses are high quality fuses and have a minimum power dissipation. If technical datas are ok and the fuse doesn't become too hot -> go to an electronics store. |
#684
|
|||||
|
|||||
![]() Thank you Matthias,
I am planning on grabbing a full set of GHL fuses from aquadigital. I just want to get this up and running again as quickly as possible! |
#685
|
||||
|
||||
![]() Hello,
first, I do not speak very well English. I have profilux II and I have a problem with "dosing pump unit (4)". I have connected them to the S1-S4 (digital). Extras-->Dosing Pumps ---------------------- Dosing pump Flowrate Rate/dosing Dosings/day Description ------------------------------------------------------------------ 1 ................... 60 .............60..................1................ .A 2 ................... 60 .............60..................1................ .B 3 ................... 60 .............60..................1................ .C 4 ................... 60 .............60..................0................ Extras-->Socket functions ------------------------- Socket Function Description ------------------------------------------------------ S1.........Dosing pump 1...................A S2.........Dosing pump 2...................B S3.........Dosing pump 3...................C S4.........Dosing pump 4 S5.........Timer 1............................T5 .......... .......... .......... I have marked "Digital powerbar connected on S1-S4" I have pressed the button "Program digital......." My question: If it is correct, where the hour of starting is programmed? Thanks for all. EgaReef |
#686
|
||||
|
||||
![]() dosing pump no 4 you have 0 for dosing days, so it wont dose anything.
|
#687
|
||||
|
||||
![]() Thanks, but..
No, the unit number 4 I still do not use it. But, unit 1 started to 00:00 hours unit 2 started to 00:07 hours unit 3 started to 00:15 hours all perfect one. The hour can be changed to start? Thanks |
#688
|
||||
|
||||
![]() Hi
in dosing mode the start time can't be changed, the times are calculated automatically. If you want to dose at specific times you have to use a timer instead of the dosing function. |
#689
|
||||
|
||||
![]() thanks.
|
#690
|
||||
|
||||
![]() hello,
I have another question (I want to connect two tunze 6055): I have connected to L1/L2 the module EVG-AP 2F with a single dimmable balasts (L1) and free L2. To L3/L4 I have connected MoonWB (L3) and free L4. If I buy the module YL2-1 (connected to L3/L4), I can connect MoonWB and a tunze 6055. how can I connect the other tunze? thank you |