Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 02-07-2016, 06:25 PM
Myka's Avatar
Myka Myka is offline
Moderator
 
Join Date: Mar 2004
Location: Saskatoon, SK.
Posts: 11,268
Myka will become famous soon enough
Default

Quote:
Originally Posted by donkey77 View Post
the water is draining down the short pipe and not the tall one, does that mean i have to cut the tall one shorter a bit
By this description it sounds like you need to close the gate valve a bit more. I like to operate the Herbie with just a trickle going down the tall pipe (the "emergency drain", or sometimes called the "dry drain"). The emergency drain will get noisy if there is too much water going down it. You will need to do occasional adjustments to the gate valve by either opening a bit because there is too much going down the emergency drain or by closing it a bit because there is air being sucked down the main drain.
__________________
~ Mindy

SPS fanatic.

Reply With Quote
  #2  
Old 02-08-2016, 12:08 AM
donkey77 donkey77 is offline
Member
 
Join Date: Feb 2013
Location: saskatoon
Posts: 216
donkey77 is on a distinguished road
Default

thanks a bunch everyone