![]() Why am I getting co2 back pressure between solenoid and rector chamber???
__________________
Cheers Gary 604-319-0317 |
#2
|
|||||
|
|||||
![]() Configuration... I have Korallin reactor, with Eheim mounted to top. I am feeding Eheim off tee and 1/4" feed line to Eheim. I'm guessing too much water being forced in and causing back pressure stalling co2 flow?
__________________
Cheers Gary 604-319-0317 |
#3
|
|||||
|
|||||
![]() are you regulating water flow on the pump side or the output side
__________________
Guide to building super awesome rock structures / my tank journal http://www.canreef.com/vbulletin/sho...d.php?t=116410 |
#4
|
|||||
|
|||||
![]() Maybe turn up the operating pressure in the regulator? What pressure do you currently have on both of your gauges?
__________________
"We shall dive down through black abysses... and in that lair of the Deep Ones we shall dwell amidst wonder and glory forever." - H.P. Lovecraft Old 120gal Tank Journal New 225gal Tank Journal May 2010 TOTM The 10th Annual Prince George Reef Tank Tour |
#5
|
|||||
|
|||||
![]() This may be your issue
|
#6
|
|||||
|
|||||
![]() Gonna have to double check regulator pressures again once I start tinkering again maybe as early as today after work. As far as regulating water coming in, it makes sense that I should be matching flow in to flow out. Haven't been doing that either....
__________________
Cheers Gary 604-319-0317 |
#7
|
||||
|
||||
![]() I had the same problem as you. I to have the same calcium reactor as you and the problem was the one way check valve. It is the brass check valve correct?
I had to mount my check valve above the calcium reactor in order to keep the water from flowing out of the calcium reactor back into the check valve when the solenoid on the co2 tank was de-energized. Once the check valve compressed it would take more pressure to open the check valve again then the regulator on the co2 tank was set for. Joe |