#1
|
||||
|
||||
![]() Maybe this will help:
electrical connections" http://www.watergeneral.com/support/pdf/ELEC_DIA2.pdf And here is the piping without an auto shut off. (ASOV). Sounds to me like your ASOV is malfunctioning and needs to be replaced. Just try setting up your system like this: http://www.watergeneral.com/support/...struction2.pdf And I do not own any shares in this business, just use their technical support, although I have bought from them, hassle free |
#2
|
|||||
|
|||||
![]() Quote:
![]() But from what I've been told by Aquasafe, the ASOV won't work without back pressure. A pressure tank will still provide that pressure even though you use a gallon or two, while just a float valve on Brute can will only provide back pressure until the first time your ATO fires up and drains the teeniest bit of water out. |
#3
|
||||
|
||||
![]() I don't have a booster pump, so am not familiar with it. But that second link I sent you has the schematic for a booster pump without an ASOV like you probably have set up. Is your el wiring as in the first link? and your plumbing set up as in the second link?
|
#4
|
||||
|
||||
![]() I have looked at the second link again, the one with the plumbing connections.
Seems you need to install that check valve. Make sure that its in line properly, not reversed. It needs to be able to flow towards the RO membrane. If water is constantly flowing into your drain, even when the RO water is shut off, as at that time when the float valve shuts the ro off, Then the only shut off you have left that is supposed to be working is the electrical solenoid. This should be shutting off the incoming water. Because you do not have a check valve installed, the system will not hold pressure and the solenoid will never think that enough ro water is made. So the solenoid will reopen and the pump will turn on trying to make more ro water. But the float valve is closed, so everything will go to the drain. The flow restrictor will allow water to flow slowly to the drain, finally releasing pressure in the system and the whole operation will repeat Install the check valve would be what I would do |
#5
|
|||||
|
|||||
![]() Hillegom:
I don't have an electronic solenoid valve on my water supply, just a manual one. That would certainly work to shut everything off and would really make an ASOV redundant. Lol, well now I'm feeling just a bit sheepish. I totally forgot I ordered an ASOV and check valve from Ray and it just showed up. So I went downstairs to hook it all up and upon closer inspection (a lot closer) there is a ASOV hiding way in behind my dual membrane that I never saw there before. But there isn't a check valve. So I inserted it and now my waste water does stop (albeit after about 3-5 min) once the pressure rises enough to cut out the booster pump. So I guess that at least helps to shut it off if I forget to turn the system off. |
#6
|
|||||
|
|||||
![]() The pressure tank is not needed.
In the diagram I put up, follow the flow. The back pressure across the asov is created when the float valve (connected to output of di) in your brute is closed forcing the diaphram in the asov downward to shutoff flow coming from the third stage. The check valve is required so the asov doesn't reopen due flow in waste line removing pressure. The source of the pressure is from the supply (even with pump off).
__________________
my tank Last edited by mark; 04-21-2015 at 11:51 PM. |
#7
|
|||||
|
|||||
![]() Yeah, that's right. With it set up that way, my RO/DI system will kick in every time the ATO pump does and draws a bit of water out of the Brute. I guess now I am wondering if a pressure tank or two would supply say 2 or 3 cycles of my ATO before my RO/DI system turns on, thus prolonging the run time through the membranes to avoid what Mike was describing in his post.
That might have been why, in my brain, I thought 1 long cycle of the RO/DI was better than many quick cycles that this set I now have gives me. ... and then again, maybe I'm totally overthinking the whole thing, lol |
#8
|
|||||
|
|||||
![]() Can't help with your question #3, but this thread does appear to explain why my ASOV never turned off the waste water flow! I don't have a pressure tank on my system either. Thanks!
I removed my ASOV some time ago & for my set up it was a good thing. Less pressure drop between the sediment/carbon stages & the RO membrane, which should help output performance. I don't miss the ASOV at all since I never let the system run unattended. Too many minor floods & potentially worse floods for me to trust Auto anything when it comes to water production. I monitor water pressure with 2 gauges & TDS with 2 dual TDS meters. House pressure is good, no need for a booster pump. With an incoming TDS in the 170 range (except on the rare occasion the city switches me to the Duteau Creek water source), it's best for me not to run the system in short "top off" type bursts. It takes a good 2-4 minutes after opening the source water valve for the RO output to drop down to 1. On initial start the RO output TDS is pretty close to source water TDS (over 100) for at least half a minute. This would really do a number on my DI media, so the first half gallon of RO water goes into a waste bucket, then I make about 5 gallons of RO water before I even think about sending anything through my DI stage. This has worked very well for me, may not work for everyone, especially those with less time on their hands to keep an eye on things. May also be unnecessary for folks with very low source TDS, say 10 or less, like you lucky folks in most of the greater Vancouver area.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() |