I desire mine to do most of the same things as yours. I've used some different language and it works without issue.

Set ON
Min Time 006:00 Then OFF (keeps the pump from turning back on for 6 minutes if one of the switches shuts if off)
If Sw5 OPEN Then OFF (upper water level limit switch so that the tank doesn't overflow if the 'overflow' becomes blocked)
If Sw3 CLOSED Then OFF (This is a water on the floor sensor)

I think your feed program is wrong. If I wanted to use that feature to shut my return pump off for 6 minutes I would say this:

If FeedD 006 Then OFF
__________________
"We shall dive down through black abysses... and in that lair of the Deep Ones we shall dwell amidst wonder and glory forever." - H.P. Lovecraft

Old 120gal Tank Journal
New 225gal Tank Journal
May 2010 TOTM
The 10th Annual Prince George Reef Tank Tour
Reply With Quote
  #2  
Old 04-15-2014, 10:10 AM
kole kole is offline
Member
 
Join Date: Jun 2011
Location: Conception Bay South NL
Posts: 134
kole is on a distinguished road
Default

So without a fallback statement does your pump restart after an outage? I use the feed statement to turn the pump back on after sw1 is activated. After your switches are activated will the pump come back on by itself or do you have to do something?
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:41 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.