![]() Are you on a well, or city water?
What is the pressure? It should be at least 60psi If you have that, then your membrane has a hole in it. And your DI filter is depleted. Barring everything else, your DI will bring the TDS down to 0. Check the TDS of the water coming out of the ro membrane. It should be about 95% less than your tap water. |
#2
|
||||
|
||||
![]() Quote:
__________________
27gal Reef |
#3
|
|||||
|
|||||
![]() Are you sure your rodi unit is connected properly.....sounds like their is no flow restricter installed or the flush valve is open
__________________
500G Mixed Reef ![]() __________________________________ Electrician, Electronics Technician, I can help with any electrical questions you might have!! __________________________________ Kevin |
#4
|
||||
|
||||
![]() +1
That valve is for flushing the membrane. |
#5
|
||||
|
||||
![]() sent u a pm with a diagram and video
|
#6
|
||||
|
||||
![]() I actually found the video very helpful however I have different valve on mine that I might consider throwing out.
Here is my sad candy coral
__________________
27gal Reef |
#7
|
||||
|
||||
![]() I actually found the video very helpful however I have different valve on mine that I might consider throwing out.
http://imgur.com/CooXy6z Here is my sad candy coral http://imgur.com/2ZAVF9E
__________________
27gal Reef |
#8
|
||||
|
||||
![]() That is a precision type of valve. Forget the name. The last person to install that probably used it as a flow restrictor. If so and if everything else is hooked up properly, then you adjust that valve so that when you get 1 liter of ro water, 4 liters of waste are produced.
Do you have a pic of the other side of the ro membrane housing? |