Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 12-31-2013, 10:19 PM
allie_san's Avatar
allie_san allie_san is offline
Member
 
Join Date: Apr 2010
Location: Edmonton, AB
Posts: 41
allie_san is on a distinguished road
Default

Quote:
Originally Posted by Reef Pilot View Post
First, before you start, have your reagent pack cut, and opened/shaped ready to pour the powder into the vial. It is very important that you get all the powder into the vial really quick without spilling any.

Be sure the vial is always clean, inside and out.

After the C2 comes on, note the exact time in seconds and pour the reagent into the vial, and swirl for almost the full 3 min. It is very important that all the powder is dissolved and no micro bubbles. Then insert, close, and hold the button until the 3 min timer shows on the display. If you just press and release, you will get a reading but it will not be accurate. After the 3 min counts down, you will get your reading.

My Hanna checker readings are consistently accurate, and usually don't vary more than .01 when I have done more than one test.

Before when I was using the color test kits, they would read zero while the Hanna would read .6 and higher. It is very hard to distinguish white, and a slight off white, and they always read too low.

I use the Low Range Hanna Phosphate Checker, model HI 713 and reagents are HI 713-25.
Are you using RO water to rinse out the vials? I've been just rinsing them under the tap..which seems pretty stupid in retrospect now...

I've been emptying my packets over a piece of paper now, seems easier than trying to get it all out of the little packet into the little vial without spilling any.
Reply With Quote
  #2  
Old 12-31-2013, 10:33 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

Quote:
Originally Posted by allie_san View Post
Are you using RO water to rinse out the vials? I've been just rinsing them under the tap..which seems pretty stupid in retrospect now...

I've been emptying my packets over a piece of paper now, seems easier than trying to get it all out of the little packet into the little vial without spilling any.
Yes, I rinse in RO water after every use. And after filling with water and then powder I also rub the outside of the vial with a towel to be sure it is clean and no finger prints before inserting into the checker.

I cut the packets and make a crease in them, to funnel the powder. I also use the scissors tips to open up the ends inside to be sure no powder stays trapped in there. Then I just hold the vial at a 45 degree angle (easy to over spill powder if held straight up) and tap in the powder from the funnel crease in the packet.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
Reply


Posting Rules
You may not post new threads