#1
|
|||||
|
|||||
![]() Quote:
Well kinda...like 1/3rd...without salt...without sand....without rock...and without livestock. Seems like you are putting effort to fast pace everything recently ![]()
__________________
You wouldn't want to see my tank. I don't use fancy equipment and I am a noob ![]() |
#2
|
|||||
|
|||||
![]() Woohoo, wetness! Sweet
![]() |
#3
|
|||||
|
|||||
![]() Quote:
Yes excited nervousness. 1/2 full now....... ![]()
__________________
Feed the bear goodies, make a new friend, don't feed the bear............... 8' - 165gal Reef DIY LED's Build 2012 Nano Contest Winner Febuary 2013 POTM Winner 300 gal + 60 gal Complete DIY Build |
#4
|
||||
|
||||
![]() looking good buddy, you must be nervous as hell with that much water. Hope it all is good and you dont end up with a mess. Fingers crossed for ya bro!
|
#5
|
||||
|
||||
![]() Yea it was a cool build to see in person when I picked up that bulkhead. My GF was jealous she didn't get to check it out haha. It's very well designed and built system. Wish I had those building skills! When I upgrade to a 1-300 gal tank I'll be going to a store lol.
__________________
27gal Reef |
#6
|
|||||
|
|||||
![]() Showed your tank filling to my niece she wanted to know if you could swim in it gotta love the minds of kids
__________________
![]() |
#7
|
|||||
|
|||||
![]() Well it's full & flowing at half the pump volume because I'm waiting for a replacement power supply for one of my WaveLine DC1000. ZERO plumbing leaks so I'm very very happy with that but I am going to have to add a balancing line to join the 2 return side together, not a big deal.
![]() ![]() Quote:
![]() Quote:
Quote:
![]()
__________________
Feed the bear goodies, make a new friend, don't feed the bear............... 8' - 165gal Reef DIY LED's Build 2012 Nano Contest Winner Febuary 2013 POTM Winner 300 gal + 60 gal Complete DIY Build |
#8
|
|||||
|
|||||
![]() WOW!!! Absolutly huge build! Coming along great. That sump is definatly a work of art. nice clean plumbing. Great job on the tank aswell. I know if it were me it would of looked like the caulking gun exploded, it would of been all over the wife, the dog and not to mention my 2 yo hahahaha.
|
#9
|
||||
|
||||
![]() Quote:
|
#10
|
|||||
|
|||||
![]() Quote:
If you base design conditions on a 1" different between chamber heights, a single 2NPS line will only flow around 1000GPH max. Given the flow rate of each pump, the number of pumps on each side, the fact each run on current switching devices and you plan on adjusting flow rates on each line with gate valves you will need the capability of a larger flow rate than say 1000GPH. Also if one pump is shut off for maintenance or other reasons this number will have to increase further. 1" design difference may also be too extreme as well when you consider how your ATO will work. Ultimately 3-4 2NPS connection pipes may be needed, whether there is room for this or not is the question. Since you're against gaps under baffles the best solution may be removing the baffles and trimming the width, then adding another baffle that connects the chambers of each side. Pic for ref: ![]() Last edited by sphelps; 08-12-2013 at 05:41 PM. |