#1
|
|||||
|
|||||
![]() Quote:
Nothing wrong with the setup, just kinda hard to work with |
#2
|
|||||
|
|||||
![]() okay, if i got the orientation of your sump correct.
this should work. if section 1 is at the back of the tank section 2 is front left side section 3 is front right side tank drains into 1 flows under baffle into 2 (refugium) over baffle into 3 (return pump and skimmer) you'd need another baffle in section 2 just behind the current baffle. (colored in red) this baffle would go from the bottom of tank, and would be shorter than baffle leading to section 3 this way, water flowes under baffle 1 (bubble trap) flows up over new baffle (into refugium) and then over 3rd baffle into return chamber! make sense?!? ![]()
__________________
- S H A O - Last edited by smokinreefer; 07-25-2013 at 06:29 AM. Reason: add pic |
#3
|
|||||
|
|||||
![]() Shao, if he has room for the skimmer and return together in one chamber, there's a chance of micro bubbles ...
Another option would be to use a HOB 'fuge with a powerhead or such to fill it. A small 'fuge would be easy to clean out when removed thus elimating a messy sump cleanup headache With this idea, trapezoid is tank drain ( and socks if desired ) Left is skimmer and right is return No baffle mods needed |
#4
|
|||||
|
|||||
![]() Was thinking that a HOB fuge would be okay and resolve a lot of issues. If not I think I am gonna have to add baffles and that might be more trouble then it's worth. I won't put the skimmer and return in the same as I don't want to run the rail of micro bubbles.
|
#5
|
|||||
|
|||||
![]() Quote:
would you be able to have your skimmer in section 3 positioned so the output goes over the back baffle, back into section 1, where the display tank drains? eliminating the issue of micro bubbles.
__________________
- S H A O - |