Default Apex outlet wont turn off

Having a weird issue with number 3 outlet on the apex controller. Its connected to a Hydor powerhead which for some reason wont shut down when i select "off" in the apex control menu. All other outlets turn on and off fine... any ideas?
__________________

- 33 Gal - 20Gal Sump, MP10/Hydor Powerheads, Aquaticlife 4x T-5HO, Vertex IN100, TLF w/Biopellets, Tunze ATO

-45GAL Build in Progress!-
Reply With Quote
  #2  
Old 04-28-2013, 10:09 PM
Maverick00 Maverick00 is offline
Member
 
Join Date: Mar 2010
Location: Vancouver Island
Posts: 380
Maverick00 is on a distinguished road
Default

well from what ive read apparently low power devices can somehow manage to avoid shutting down if not connected to relay outlets 4 or 8.
__________________

- 33 Gal - 20Gal Sump, MP10/Hydor Powerheads, Aquaticlife 4x T-5HO, Vertex IN100, TLF w/Biopellets, Tunze ATO

-45GAL Build in Progress!-
Reply With Quote
  #3  
Old 04-28-2013, 10:26 PM
BlueTang<3's Avatar
BlueTang<3 BlueTang<3 is offline
Member
 
Join Date: Mar 2009
Location: Stony Plain, Alberta
Posts: 1,641
BlueTang<3 is on a distinguished road
Default

Yeah I believe outlets 4 and 8 have triac relays I think ?? Trying to find some pages in it I have an older controller but trying to set up the self cleaning head but can't remember when I had read that.
__________________
360 gallon sps reef, 180 gal sump, bubble king supermarine 300, 4xmp40Wes, 2 x 6215 tunze waveboxes, 4 ghl mitras



360 Reef Tank
Reply With Quote
  #4  
Old 04-29-2013, 01:22 AM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

1,2,3,5,6,7 outlets are TRIACS. Which have what is called Leakage current. They are allways on so to speak. They need a larger load connected to them to be acctually OFF. It's quite common actually. Everyting in industrial control is like that. A lot of times, with a LED indicator light or something, we need to put a resistor in with it in parallel to load the output so that it draws the leakage current down.

Swapping your pump to 4 or 8 outlet will solve it. They are true dry contact relay outputs
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 12:04 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.