#1
|
|||||
|
|||||
![]() Yes I realize the elbows reduce the flow a bit but I want to know more about the difference between the 1" and 1.5 " the idea behind the head pressure is the weight in water pushing back against the flow so wouldn't the bigger pipe add more weight in water ?
|
#2
|
|||||
|
|||||
![]() While in theory, yes there is more water weight going with 1 1/2" over 1", but that's only really 1 part of the story. Friction loss is a very big deal to contend with. And 1 1/2" pipe has significantly less friction loss than 1". The barracuda pump can easily handle the head pressure of either, but you'll get way more flow with the 1 1/2". I'm running 1 1/4" piping on my barracuda with probably 10'-12' of head and I figure I'm in the 1400 gph range or so.
|
#3
|
|||||
|
|||||
![]() Same here, I noticed a big flow improvement when I switched my Hammerhead from 1" to 1.5". I'd run the 1.5" for sure.
__________________
![]() They call it addiction for a reason... |
#4
|
|||||
|
|||||
![]() Damn you guys I didn't want to have to run more pipe lol but looks like I will be making another trip to the plumbing supply store
|
#5
|
|||||
|
|||||
![]() Lol, I know exactly how you feel. Re-plumbed mine 3 times
![]() Make sure you put a ball valve on the discharge side to be able to regulate flow a bit. Those barracuda's can flow tons of water. The nice thing with them too is if you upgrade, you can just get a hammerhead impeller and swap them out. That's what I did (but in reverse, bought a used hammerhead and swapped to the barracuda for like $30) |
#6
|
|||||
|
|||||
![]() I am sure glad I ran a 2.5 inch for the overflow line now , I am sure getting tired of running pipe I am thinking I will leave the 1" as a line for a closed loop if I want it
Thanks for the advice guys |