![]() Myka, I agree with your statements but be aware I did have someone enter my house twice daily although their experience with aquariums is nil and their prime objective was not related to the tank. I also had someone with experience on call and checking on the tank every few days. While I would have loved to have someone with great experience in aquariums checking my tank more frequently my remote location makes this rather difficult. Also note this failure occurred very quickly within 12 hours if you can believe it. By the time the issue was noticed the damage was done.
In regards to top off water supply yes perhaps a smaller amount of available supply would be better but I have issues with this as well. If I leave for an extended period of time then IMO it's better to have enough top off water available for the entire time otherwise I have to rely on others fulling a container with RO water which in the past is something that has gone very badly for myself personally and others I know as well. So for extended trips the amount of evaporation water available IMO will need to exceed that of the amount that cannot cause damage. Using the small bucket approach to me is not redundancy as it basically adds the need for another top off system which in fact increases your chances of failures rather than decreases it. While obviously there are many way to do this I stand by my method but agree more redundancy is needed but more related to what I mentioned earlier and perhaps additional floats or something else along these lines. Lastly I draw attention to my last request in the first post of this thread. |
#2
|
|||||
|
|||||
![]() Jorjef, automation is tha bomb, but it's definitely not a fail-safe.
Quote:
![]() I can't see how failing to refill a top off container could come to a situation as bad as the one you were dealt with though. The Tunze Osmolator quits pumping when it runs out of water, and the replacement pump is $30. If my sump runs out of water my Poseidon return pump will also quit operating. If the Poseidon happens to burn out I have a spare pump on hand with the appropriate plumbing fittings ready to go. The system is quite fine to run without the sump for a few days (the biggest consequence being no dosing), although the aquarium maintenance company would surely notice long before that. The company tested the tank for the "big three" weekly and reported to me if they were out of range for appropriate instructions on rectifying the problem. There are always those things we just don't think about though, and those are the things that kick our butt and crash our tank. In your case, you didn't think about the repeated power outages. Who would? I've certainly never experienced such a thing. Last edited by Myka; 07-29-2012 at 12:06 AM. |
#3
|
|||||
|
|||||
![]() The problem relates to filling the container once empty especially if relying on others or equipment in your absence, doing so manually from an RO increases chance of flooding and doing so automatically requires additional ATO which doesn't add redundancy but rather another point of possible failure.
|
#4
|
|||||
|
|||||
![]() Quote:
When I was a carpenter, my old boss used to always say, "You gotta be smarter than the tool." ****ed me off at the time, but now I laugh. Yep, that is so true. In this case, we have to be smarter than our gadgets. Anyway, I'm sure you're tired of this thread by now...I would be. Feel free to hit me up for frags when/if you come to that point in the future. Last edited by Myka; 07-29-2012 at 12:08 AM. |