![]() |
#11
|
|||||
|
|||||
![]() Missed the point entirely.
His post was intended to help people who already have their plumbing set up. If they could or were able to re-do it properly then I'm sure they would. Barring that, his advice is sound. And you added nothing, only distracted from a valid point. If you wish to start a thread called "everybody should do their plumbing right the first time', then feel free to do so. Anyways , I won't reply on this further because it only serves to further distract people from the original message.
__________________
There's only two people in the world that I trust. One of 'em's me,...the other's not you. |
#12
|
|||||
|
|||||
![]() I assure you I didn't miss your post, the original message is flawed which is why I spoke up. The advice to fix an issue with increased inspection as appose to fixing it permanently when it is cheap and easy is terrible advice and accomplishes nothing. A siliconed connection will give no advanced notice before blowing off, if the fitting was inspected the day prior it would have likely looked fine. This issue could be fixed with less than $10 and 5min of time, this is what advice should be given. Just admiting part of your plumbing requires frequent inspection suggests you have a problem, don't fix it by checking it more often
![]() |
#13
|
||||
|
||||
![]() I had some faulty bulkheads from JL blow on me a couple weeks ago. Had I checked them, I would have noticed they were getting salt creep in areas there shouldn't be. Instead, one morning I had not one but TWO of the bulkheads fail and start dumping water from the overflow. By some miracle I was standing next to the tank when it happened (fixing a skimmer that was going crazy from an unknown reason nonetheless).
|
#14
|
|||||
|
|||||
![]() Exactly my point.
Yes if you know that you have substandard equipment you should replace it. That is completely obvious to everyone and again misses the entire point of the post. If everyone had complete and perfect knowledge, yours would be the only point. Since that little world does not exist, we will go with helpful reminders like this one. Even perfect equipment, perfectly installed, will still fail. To not keep an eye on things is ludicrous. "The advice to fix an issue with increased inspection as appose to fixing it permanently when it is cheap and easy is terrible advice and accomplishes nothing."Neither he nor I ever suggested that he leave it crappy and just watch it from time to time. Better bone up on your reading skills. Nowhere in this entire post does it say to fix things by checking on them regularly instead of doing it properly. It just says to regularly inspect your equipment which is perfectly sound advice. Your reading of the post is the only thing flawed. His comment was a helpful suggestion to help out his fellow reefers.
__________________
There's only two people in the world that I trust. One of 'em's me,...the other's not you. Last edited by jtbadco; 05-23-2012 at 01:32 AM. |
#15
|
|||||
|
|||||
![]() It was never posted how or if the issue would be fixed, the point of my posts were to bring clarity to this matter and perhaps some helpful advice to the OP and others that the lesson here is more to fix potential issues rather than just promoting further inspection. It seems possible that one might not realize silicone is a poor adhesive for plastic hose and that is the only way to make such a connection so rather than making a solid connection the hose is siliconed on again and then inspected weekly but only to fail later down the road between inspections or when away from home.
As for parts just failing for no reason, it's unlikely to say the least. Two bulkheads failing instantaneously for example due to faulty parts... I would question that and put blame on stressed connections. You have to remember pipe and water has weight and combined with moment arms from rigid pipe creates high torque which can snap cheap sch20 or even 40 bulkheads if the pipe is not properly supported. There is more than one way to look at things and adding to someones recommendations and posts is hardly talking away from them. Take it for what it's worth, if that's a an eye opener to fix your own issues before something similar happens good stuff but if you'd prefer to blame all your issues on an imperfect world so be it. |
#16
|
||||
|
||||
![]() I see both points.Yes correctly done installations are less prone to failure but even the best comercial systems and plants have routine inspections to find problems before disaster strikes.I like this topic.The "what if" scenario is always on my mind.
|
#17
|
||||
|
||||
![]() Quote:
|
#18
|
|||||
|
|||||
![]() I think the real message here is don't silicone plumbing parts together, use plumbers PVC cement. I do however suggest frequently inspecting pump seals. Anyone who owns a Reeflo pump knows that they can suddenly start to leak from around the drive shaft seal.
__________________
"We shall dive down through black abysses... and in that lair of the Deep Ones we shall dwell amidst wonder and glory forever." - H.P. Lovecraft Old 120gal Tank Journal New 225gal Tank Journal May 2010 TOTM The 10th Annual Prince George Reef Tank Tour |
#19
|
|||||
|
|||||
![]() I would assume that most PVC cement is reef safe? Or is there special brands people use.
|
#20
|
|||||
|
|||||
![]() Yes any PVC cement is safe it is just advised to wait at least 1 hour after application before start up. Keep in mind PVC cement is only effect on rigid PVC parts/pipe. Spa flex can be glued into rigid PVC fittings but may require a non standard cement for best results.
|