Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 03-15-2012, 04:00 AM
Madmak's Avatar
Madmak Madmak is offline
Member
 
Join Date: Feb 2012
Location: Chestermere, AB
Posts: 432
Madmak is on a distinguished road
Default

Found a ReeFlo Barracuda pump today for the closed loop

Also found some heavy duty leveling legs for the metal stand. They got installed and the stand is getting a coat of gloss white paint.

Siliconed in the new overflow today as well. It is 5"X5"X48" and will be using a bean animal style drain with 1" pipe.

All my loc-line came in today as well and I installed some of the closed loop lines on the bottom of the tank. Can't wait to have almost 5000 GPH flow without any equipment showing, no powerheads, no cords





Reply With Quote
  #2  
Old 03-15-2012, 09:54 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Cool. Hope that does the trick
Reply With Quote
  #3  
Old 03-16-2012, 12:11 AM
Cade's Avatar
Cade Cade is offline
Member
 
Join Date: Nov 2011
Location: Victoria BC
Posts: 110
Cade is on a distinguished road
Default

Vary cool, good luck!
__________________
Tankless and Planning
Reply With Quote
  #4  
Old 03-16-2012, 03:57 AM
mseepman mseepman is offline
Gold Member
 
Join Date: Aug 2007
Location: Vernon
Posts: 2,529
mseepman is on a distinguished road
Default

Looking good. That pump looks like it's already put in a few good years!
__________________
Mark...



290g Peninsula Display, 425g total volume. Setup Jan 2013.
Reply With Quote
  #5  
Old 03-16-2012, 07:08 AM
Madmak's Avatar
Madmak Madmak is offline
Member
 
Join Date: Feb 2012
Location: Chestermere, AB
Posts: 432
Madmak is on a distinguished road
Default

Thx, it is coming along ok.

The pump was in the box of my truck on the way home on a gravel road, hence the dust. I think it is 2010 model, based on the seller and the dates on all the PVC and spa flex it came with and used on a FW tank. Also came with 3 2" double union ball valves and a 2" check valve. Kijiji is my friend
Reply With Quote
  #6  
Old 03-25-2012, 07:04 AM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

I would add 6 more of those feet if it was me. Reasons: there only 1/2" bolts and not structual bolts, your stand is only 1/8" thick tube & the bolts you used are very tiny and don't take much force to break.
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
  #7  
Old 03-25-2012, 07:36 AM
bauder1986's Avatar
bauder1986 bauder1986 is offline
Member
 
Join Date: Apr 2009
Location: Edmonton, AB...find the earie glow of the T5 lights coming from a house lol
Posts: 439
bauder1986 is on a distinguished road
Default

Quote:
Originally Posted by The Grizz View Post
I would add 6 more of those feet if it was me. Reasons: there only 1/2" bolts and not structual bolts, your stand is only 1/8" thick tube & the bolts you used are very tiny and don't take much force to break.
Another solution i see greg, if you will help me with this(either criticize or elaborate) I noticed that the ends of the tubes where the feet screw into are open. What you can do to solve the issue of having all the weight transfered to only the outer edges of the tubing is insert a block like this through the ends to line up with the bolts.



The block would have to be a very snug fit but it will properly transfer the weight of the tank from the pillars down through the block and into the threaded foot bracket instead of through the pillars and into the very thin walls of the square tubing which would buckle under the weight over time.


but greg is one hundred percent bang on about the 1/2 bolts.....they should be at least 3/4" bolts.....but, if you were to insure that no more then 3/16" of thread was out it would REDUCE the risk of snapping the bolts but it wouldnt be a full garuantee....
Reply With Quote
  #8  
Old 03-25-2012, 07:49 AM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

I would have opted more for drilling right though the tube, 1/4" square washer plate both side with a nut on both sides. But still add more feet.
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:24 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.