![]() So what do you figure is a fair price for two guys for a day? A grand is fair where I come from. Good on ya guys for diy'ing the job.
|
#2
|
|||||
|
|||||
![]() wingedfish, no problem a $1000 for labour and probably would have agreed to $2500 a unit with installation, to cover markup on the unit and other materials. Just couldn't do $4000.
bkelly, again the insulation shouldn't be wet. No expert but I'd replace.
__________________
my tank |
#3
|
|||||
|
|||||
![]() Not only does it remove the humidity, it actually does recover the heat.
Inserted a temp probe in the ducts a couple of feet from the unit (house side) exhaust 22°, fresh air 13° with the outside air measuring -9°C.
__________________
my tank |
#4
|
|||||
|
|||||
![]() Good to hear.
__________________
There's plenty of room for all God's creatures. Right next to the mashed potatoes. |
#5
|
||||
|
||||
![]() There are multiple ways to do HRVs
A stand alone system with supplys in the bedrooms and living room and exhausts in the kitchens bathrooms is best but alot of labour $$$ but you can also just tie it into your supply and return ducts off a forced air system not as good but substainally cheeper
__________________
250G DD LED SPS R.I.P. 180G LED SPS 80"x36". 300G custom build Owner of Mountain Ridge Heating and Gas Class A gas fitter, HVAC |
#6
|
|||||
|
|||||
![]() Fully ducted would have been best but since I was installing in a house complete with finished basement still think having a separate stale intake with fresh air tied to furnace a good compromise (middle picture). Think my numbers also show it worked out okay.
Here's a diagram of installs ![]()
__________________
my tank |
#7
|
||||
|
||||
![]() yes.
how did you do picture 2 if your house is finished? picture 2 is better than picture 3 but very rare to see as you also need the house open to do that. tell u the truth Ive heard of it but never actually seen picture 2 style. most people do picture 1 or 3.
__________________
250G DD LED SPS R.I.P. 180G LED SPS 80"x36". 300G custom build Owner of Mountain Ridge Heating and Gas Class A gas fitter, HVAC |