Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 02-07-2012, 02:22 AM
reefwars reefwars is offline
R.I.P.
 
Join Date: Apr 2010
Location: Calgary, AB
Posts: 6,186
reefwars will become famous soon enough
Default

Quote:
Originally Posted by wmcinnes View Post
finally went out and got some pumbing and started to piece it together! unfortunately i all the LFS seemed to have an abundance of ball valves but no gate valves. I had to order the gate valves online so until they come there is not a whole lot I can do..

Waiting on a few things to arrive:
~75lbs of MarcoRocks from Eli @ CaCo3Reef!
2 x 300W Eheim Jager heaters
Refractometer
RO/DI float valve
3 x 1" Gate Valves

Also the QT tank is still cycling and I am starting to see the nitrite spike so it should be somewhat close to finishing.. Can't wait to be able to get some fish in there. Im hoping for a Sailfin Tang Desjardini and a pair of False Percula Clowns to start!




the sailfin will be too large for a 90g they grow very fast, beautiful fish though


why three gate valves????
__________________
........
Reply With Quote
  #2  
Old 02-07-2012, 03:10 AM
wmcinnes's Avatar
wmcinnes wmcinnes is offline
Member
 
Join Date: Jan 2012
Location: Edmonton
Posts: 338
wmcinnes is on a distinguished road
Default

Quote:
Originally Posted by reefwars View Post
why three gate valves????
I'm doing a Herbie overflow so I need one on my main drain line to control the syphon, one on my return to control flow and complete isolation when i need it, and one on the tee'd-off line from the outlet of the return pump to the refugium.

Probably only really needed two but they are already ordered..
__________________
Wayne

Rainforest of the Sea
First 90g Reef

Last edited by wmcinnes; 02-11-2012 at 10:40 AM.
Reply With Quote
  #3  
Old 02-10-2012, 06:46 AM
wmcinnes's Avatar
wmcinnes wmcinnes is offline
Member
 
Join Date: Jan 2012
Location: Edmonton
Posts: 338
wmcinnes is on a distinguished road
Default

Canreef.. if you think your water is bad, you havent seen mine..


Before on the Left, After ~250G on the right...

This is my first stage pre-filter... the second stage carbon block and third stage 1micron filter werent much better... unbelievable.

safe to say I will not be drinking any of my tap water any time soon. :uhoh2:
__________________
Wayne

Rainforest of the Sea
First 90g Reef

Last edited by wmcinnes; 02-11-2012 at 10:41 AM.
Reply With Quote
  #4  
Old 02-10-2012, 08:05 AM
Bblinks's Avatar
Bblinks Bblinks is offline
Moderator
 
Join Date: Oct 2010
Location: Coquitlam B.C.
Posts: 3,033
Bblinks is on a distinguished road
Default

Quote:
Originally Posted by wmcinnes View Post
Reef Central.. if you think your water is bad, you havent seen mine..


Before on the Left, After ~250G on the right...

This is my first stage pre-filter... the second stage carbon block and third stage 1micron filter werent much better... unbelievable.

safe to say I will not be drinking any of my tap water any time soon. :uhoh2:
I was just gonna said that is some high reading from the TDS meter, I guess I should be glad to have in coming water reading at 10ppm.

Good looking build, but just out of curiosity, if you are doing a herbie should you use gate valves instead of regular on and off valves? I didn't see in the picture. It would be a lot harder to control water flow with a regular union valve.
__________________
Though a tree grow ever so high, the falling leaves return to the root.

300DD - 140DD



TOTM Fall 2013
Reply With Quote
  #5  
Old 02-10-2012, 09:03 AM
wmcinnes's Avatar
wmcinnes wmcinnes is offline
Member
 
Join Date: Jan 2012
Location: Edmonton
Posts: 338
wmcinnes is on a distinguished road
Default

Quote:
Originally Posted by Bblinks View Post
I was just gonna said that is some high reading from the TDS meter, I guess I should be glad to have in coming water reading at 10ppm.

Good looking build, but just out of curiosity, if you are doing a herbie should you use gate valves instead of regular on and off valves? I didn't see in the picture. It would be a lot harder to control water flow with a regular union valve.
Yeah my TDS is upwards of 2500, just ridiculous.

True and that is why my plumbing is at a standstill at the moment. Im waiting for my gate valves to come from concept in calgary before I can finish plumbing the system. I threw in a few heaters in order to get free shipping and sure enough they were on backorder so I could be waiting a while before they arrive The ball valves in the picture are actually 3/4" and are being used in the manifold for my reactors..
__________________
Wayne

Rainforest of the Sea
First 90g Reef

Last edited by wmcinnes; 02-11-2012 at 10:42 AM.
Reply With Quote
  #6  
Old 02-11-2012, 02:09 AM
wmcinnes's Avatar
wmcinnes wmcinnes is offline
Member
 
Join Date: Jan 2012
Location: Edmonton
Posts: 338
wmcinnes is on a distinguished road
Default

Gate valves and Jager 300W,250W heaters came today! I am actually super surprised they came so fast because they were on backorder at Concept! I'm working nights for the next bit but hopefully I can find some time to finish up the plumbing! Check back for updates
__________________
Wayne

Rainforest of the Sea
First 90g Reef

Last edited by wmcinnes; 02-11-2012 at 10:43 AM.
Reply With Quote
  #7  
Old 02-11-2012, 10:46 AM
wmcinnes's Avatar
wmcinnes wmcinnes is offline
Member
 
Join Date: Jan 2012
Location: Edmonton
Posts: 338
wmcinnes is on a distinguished road
Default

I got bored on nightshift at work so I did a little editing to the thread. Introduced myself a little better on the first post and made it look nice.. Clearly work was busy tonight...
__________________
Wayne

Rainforest of the Sea
First 90g Reef
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 02:49 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.