Quote:
Originally Posted by Myka View Post
Could be a BC/AB difference too. I should dig out my BC Building Code book...wonder where it is.
I think it depends on material as well could be 5/8 for ply but should be thicker for OSB and could be some weird number like 23/32" which is basically 3/4". Also joist span is between 16-24" typically so that can play a role as well.
Reply With Quote
  #2  
Old 12-07-2011, 11:08 PM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
I think it depends on material as well could be 5/8 for ply but should be thicker for OSB and could be some weird number like 23/32" which is basically 3/4". Also joist span is between 16-24" typically so that can play a role as well.
two layers of 19/32" glued and screwed on 6" centers. will give you the min code of L360 deflection, if it is on properly sized joists on 16" centers. problem is so many builders cut corners and the L360 is a min code which in many cases is not sufficient for natural stone or larger tiles (these can require up to L480)

with the building boom over the last 15 years there are a lot of bad builders that would not put the second layer of plywood, or neglect to glue the two layers of plywood togeather, or spaced the screws every 8". no glue and a larger screw spacing can actualy add up to a lot of money in a large tiled area. you figure the recomended aplication of the glue is two tubes per sheet. at 12 bucks a tube combined with less screws you can save over 100 bucks in a 16x16 room. make this a subdivision with 40 houses, and other cost saving measures it can add up to a lot for a developer.

if you realy have a 1.25 or 1.5" subfloor, with ceramic tiles you would be fine.. the only thing I would recomend is adding extra blocking between the joists under the area to help spread the weight over more joists, which also stiffens a floor.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.

Last edited by StirCrazy; 12-07-2011 at 11:11 PM.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:05 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.