#1
|
|||||
|
|||||
![]() Your variable flow restrictor which is on the front of the unit with black handle ( I believe) needs to be adjusted. Adjust it until you get a 4 (waste) to 1 (ro) ratio. Its either 4 to 1 or 3 to 1. I cant remember. You probably have the flow restrictor open all the way so right now you are essentially flushing the membrane.
|
#2
|
|||||
|
|||||
![]() These instructions may help:
http://www.aquasafecanada.com/aquari...allation-page/ |
#3
|
|||||
|
|||||
![]() ![]() |
#4
|
|||||
|
|||||
![]() How would he "flush" his membrane?
|
#5
|
||||
|
||||
![]() Piped wrong, look at sphelps's picture.
You are coming out of the prefilters and through the flow restrict and into the membrane with no restrict or on the waist line. |
#6
|
|||||
|
|||||
![]() By opening the valve on the flow restrictor, the item with the black lever. In his photo, the lever is shown in the 'flush' position. To make water, the lever goes 1/4 turn, much like any conventional ball valve. Having the valve open reduces backpressure in the membrane housing so all the water bypasses along the outside of the membrane, flushing it. Once the handle is turned 90 degrees, the built in restrictor creates the required amount of backpressure in the waste line to cause some of the water to get pushed through the membrane and purifying it.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() |
#7
|
||||
|
||||
![]() Thanks guys. I bought the item used and this is how it was setup. I will try to re-plumb it.
So I should turn the black valve (quarter turn) 90 degrees to the close position for it to function? Last edited by -=James=-; 11-20-2011 at 11:58 PM. |
#8
|
||||
|
||||
![]() Although it probably came that way from the vendor, there is no need for the GAC "Taste and Odor" filter that is plumbed in after the DI cartridge. After the water leaves the DI stage it is as clean as your system can make it.
Also, contrary to how your vendor originally made the system, a horizontal DI stage is a fundamental configuration error. Remove the DI stage from its clips, and orient it vertically with bottom up flow. Additionally, we recommend against running the DI out put to a pressurized storage container. Be happy to explain why if needed via PM - not interested in educating the ebay vendors! Russ |