![]() |
|
#1
|
|||||
|
|||||
![]() I'd consider looking at something with a 75 gpd membrane. Production may be a little slower than 100 gpd, but the rejection rate is generally better, so if you plan to add DI stage, that will more than likely last longer. This all depends on your incoming TDS though. RO membrane & DI media are the more expensive components of a water purification system, so you want to maximize the quality there.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() |
#2
|
|||||
|
|||||
![]() Quote:
max PSI is 150 on a DOW 75. so ya you want to make sure you have a real dow 75. what a lot of compaines used to do and I imagin there is a good chance they still do is relable 25's as 50's 50's as 75's or 100's ect... Steve
__________________
![]() Some strive to be perfect.... I just strive. |