![]() |
|
#1
|
|||||
|
|||||
![]() What water are you using to do your dosing? if it is done with RO water then the only element added when dosing should be calcium and alkalinity, not salt.
I dose 100ml per day of both calcium and alkalinity and my salinité does not rise at all. I have a top off system with RO water and the water I use for my Bulk Reef Supply 3 parts dosing is also RO pure water. My salinity stay exactly the same, even after 6 months of dosing daily. How can dosing calcium and alkalinity in pure RO water cause an increase in salinity? Salt creep usually does the opposite and make you lose salinity over time. Also what are you using to mesure your salinity? Is it possible that your instrument is going out of wack? Some refractometer have temperature compensation but some don't, so if you are now testing at a different temperature or if your refractometer is not well calibrated, it could give you false result. I am also surprised that you have to dose so much calcium with the BRS 2 parts in a 55 gallons...how many clam or sps do you have? That seem high. Quote:
Last edited by daniella3d; 09-17-2011 at 09:04 PM. |
#2
|
||||
|
||||
![]() Dosing 2 parts in high concentration can and will increase salinity. part 1 has about 37,000 ppm calcium (calcium chloride) and part 2 has about 5,300 dkH alkalinity (sodium bicarbonate) per RHF recipe 1. Chloride and sodium are major parts of sea salts as the following image shows.
I think you over dose both parts. Per Randy, he suggests starting dosage of 1mL/gallon of each part in a heavy demand (SPS dominated) tank. Try to dose at 0.5mL/g and slowly increase from there. Measure calcium and alkalinity along the way. ![]() ![]() ![]() Last edited by George; 09-17-2011 at 09:33 PM. |
#3
|
||||
|
||||
![]() [quote=George;636797]Dosing 2 parts in high concentration can and will increase salinity. part 1 has about 37,000 ppm calcium (calcium chloride) and part 2 has about 5,300 dkH alkalinity (sodium bicarbonate) per RHF recipe 1. Chloride and sodium are major parts of sea salts as the following image shows.
I think you over dose both parts. Per Randy, he suggests starting dosage of 1mL/gallon of each part in a heavy demand (SPS dominated) tank. Try to dose at 0.5mL/g and slowly increase from there. Measure calcium and alkalinity along the way.] I feel that i am over dosing too, but only in relation to the amount of fresh water that is being added by the ATO, I think the amounts of the 2 part are off setting the amount that the ATO would add if less of the two part were used. But these amounts have seemed to have been accurate to maintain levels of 420 & 7.5 which are what I aim for, as the system is ulns. Is it worth the risk to knockback the dosed level of CA to match the level of Alk dosed correct the level of CA in the tank water & see what happens? In order to do this I would also have to do at least a 20% WC prior to correcting the levels in order to drop the salinity. Those are gonna be some pretty big swings, & then I personally feel the Ca is likely to take a dive. |
#4
|
||||
|
||||
![]() Quote:
![]() |
#5
|
|||||
|
|||||
![]() wow, very lovely tank! I thought you must have such tank if you use so much calcium.
|
#6
|
||||
|
||||
![]() Thanks Danielle, but I still think the issue of increasing sal. is due to too much CA & not enough top off / ro. water going in. I've seen pics of your tank, its awesome as well, & if your only dosing in @ 100 ml per day, that's a safer ratio than mine based on the size of setups & size of corals....
|
#7
|
|||||
|
|||||
![]() Thanks
![]() I don't know what to say, I have the opposite problem with salinity always getting lower due to salt creep and skimming, even if I dose 100ml of both per day. Quote:
|
#8
|
|||||
|
|||||
![]() Yeppers. I have this trouble too. If I don't don't do a waterchange (and adjust then), once a week I have to remove about a gallon and replace it with RO. Off the top of my head I think I add about 130 mL per day of calcium and about 100 mL alkalinity.
|
#9
|
||||
|
||||
![]() I'm going to take out some corals this coming week, in hopes that the CA demand will drop & I won't have to put so much in any more.
|
#10
|
||||
|
||||
![]() No suggestions but that is an awesome looking tank!
__________________
250G DD LED SPS R.I.P. 180G LED SPS 80"x36". 300G custom build Owner of Mountain Ridge Heating and Gas Class A gas fitter, HVAC |