#1
|
||||
|
||||
![]() - Use coarse media
- Do not overdose Co2, just enough to keep internal Ph below 7.0 but above Ph 6.4 If you have too many Co2 bubbles it will make noise and all of it will not dissolve. If your media is smaller particle size the it Will get disturbed if there is too much flow and may end up in the the circ pump intake. |
#2
|
|||||
|
|||||
![]() My RX6-Duo is online and seems to be working, but it's not completely dialed in yet. I do have a couple of tricks to pass on.
Tips Questions
![]() BRS doesn't recommend running phosphate remover in the third chamber. Instead, they recommend running phosphate remove in a dedicated upflow reactor independant of the calcium reactor. This makes sense to me. I am running the reactor with a slightly modified configuration. I have the chambers in the following sequence.
ARM COARSE - "The Complete Reactor Media" CarbiSea lists the following specifications for this media: Calcium: 416,000 ppmThe product is described as a High Magnesium Aragonite Formula. It states "Now With 3 Times More Magnesium!" The reason I mention the increased magnesium is because I wonder if I actually need to be running the BrightWell Magnesium as well? - Historically, it seems everyone recommended adding Magnesium to the reactor media, but that may have been based on the original ARM media. 1,400 ppm seems like a reasonable target to me. I guess I will need to test the levels in my tank to determine if the additional magnesium is required, but if any one has any advice on this, please let me know. Anyone else have any tricks? |
#3
|
|||||
|
|||||
![]() Thanks for the tips. I have the 4 which I'm going to swap into my system this wkend, it's currently running in the sink with vinegar/rodi. My plan was to run it internally which is good as I've already found a couple leaks. The pump is very noisey, I was hoping it would quiet down as it breaks in, my IN-180 skimmer was the same way for the first few days. I'm not planning to use a pump to feed it, the calc reactor in my system now is running via syphon, so the plan is to use the same line already in place. I have a container of the coarse ARM and ZeoMag, Arm for the main and Mag for the secondary. I think I'm running my reactor with a target PH of 6.0, I'll have to confirm on my controller when I get home but it's working well now.
__________________
Glass box with stoney stuff and fisches... |
#4
|
|||||
|
|||||
![]() Hey guys, I am in the Vertex Club.
![]()
__________________
Though a tree grow ever so high, the falling leaves return to the root. 300DD - 140DD ![]() TOTM Fall 2013 |
#5
|
||||
|
||||
![]() hey guys, I fired mine in today, using maxijet 1200, but water keeps poping out of the ph probe area? what am i doing wrong...
|
#6
|
|||||
|
|||||
![]() Quote:
Generally speaking, my Vertex reactor is fairly water tight. There is some minor salt creep at a couple of the John Guest connections, but nothing major and nothing that worries me. My guess is that you are missing the round rubber band (washer/o-ring/thingy) that fits around your pH probe? Without this band, the probe holder would not work. If you are not missing the band, but it is still leaking, try fitting the original plug back in and see if the problem persists. If it leaks with the original plug in place, then something isn't right. Check the threads to make sure they aren't stripped or damaged. Please let us know how you make out and post any tips you discover. - Brad |
#7
|
||||
|
||||
![]() I did not get any ring with my PH probe and I believe that is what I am missing here, any idea what will fit in? Also, I don have the original plug..but i do feel the ring is what it is
|
![]() |
Tags |
calcium reactor, media, rx4, rx6, vertex |
|
|