#1
|
|||||
|
|||||
![]() many articles say not to build up your Calc/Alk with your Ca Rx. Drops your PH, messes up your Calc/Alk balance, all kinds of stuff. Pick up some 2 part to build it up to your set points, then use the Ca Rx to maintain it. I did this and found it VERY helpful. Ca Rx dose equal parts Alk/Calc, so if either is off then you'll maintain an imbalance. I use a bubble counter aswell, works great, set it to 1 bubble a sec, my drip to 1 drip per second and it only took a little fine tuning to get it set.
__________________
My 150 In Wall Build |
#2
|
||||
|
||||
![]() Thanks everyone. I've set up the bubble counter and have it set to about 30 bubbles per minutes and the effluent drip rate is about the same.
OK so I've done some testing and I'll post my values. Please advise what needs to be done in terms of adjusting the Co2 and drip rate. pH controller is maintained at 6.5 Effluent test Ca is about 450ppm Kh is about 25 Ph - can't measure at the moment Tank water test Ca is below the measuring point, so below 370ppm Kh is about 6 pH is about 8.0 With respect to the effluent, are there any adjustments that I should make? Should the Ca of the effluent be higher? How can I get the effluent Ca higher? With regards to the tank water, should I buy some two part to get my Ca to respectable levels first? Looks like the Kh is slightly low as well. Much appreciated everyone for your continued help with this project. |