A cheater way is to not use a bulkhead.... if you get a male threaded 1.5" PVC fitting, a flemale one and a soft O-Ring you can make a bulkhead out of it pretty easy. Cut the female threaded fitting off to use it as a tightening nut, and now you have a 1.5" PVC fitting in a 1.5" hole. 1.5" can flow 1200+GPH pretty easy, I was getting 1200+ on mine when it was duroso, now much more as herbie. Specs say 1600GPH, with gravity feed.
__________________
My 150 In Wall Build
Reply With Quote
  #2  
Old 12-14-2010, 03:52 AM
Magma Magma is offline
Member
 
Join Date: Oct 2010
Location: Calgary, AB
Posts: 341
Magma is on a distinguished road
Default

Quote:
Originally Posted by Lampshade View Post
A cheater way is to not use a bulkhead.... if you get a male threaded 1.5" PVC fitting, a flemale one and a soft O-Ring you can make a bulkhead out of it pretty easy. Cut the female threaded fitting off to use it as a tightening nut, and now you have a 1.5" PVC fitting in a 1.5" hole. 1.5" can flow 1200+GPH pretty easy, I was getting 1200+ on mine when it was duroso, now much more as herbie. Specs say 1600GPH, with gravity feed.
not sure i understand what you said at all lol im a newbie with plumbing and this is my first tank with a sump, it was all pre-plumbed, drilled etc. im just trying to make it less noisy.
Reply With Quote
  #3  
Old 12-14-2010, 05:35 AM
Magma Magma is offline
Member
 
Join Date: Oct 2010
Location: Calgary, AB
Posts: 341
Magma is on a distinguished road
Default

http://i265.photobucket.com/albums/i...9/stockman.jpg

anyone used the stockman style before?
Reply With Quote
  #4  
Old 12-14-2010, 02:02 PM
monocus monocus is offline
Member
 
Join Date: Jan 2010
Location: burnaby
Posts: 1,024
monocus is on a distinguished road
Default stockman

i switched from a durso to a stockman and i'm very happy with it-takes up way less room and is matinence free
Reply With Quote
  #5  
Old 12-14-2010, 02:14 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

A stockman works fine but it's a little harder to make. If you can fit a 2" coupling in your overflow then use 1.25" pipe and a 1.25"x2" bushing. You'll have to drill or grind off the bushing stop so the bushing can slide onto 1.25" pipe far enough so the pipe protrudes far enough through the bushing to allow a 1.25" cap to fit. Just as with the stockman you'll need a 1/8" hole in the top of the cap to prevent siphon. You'll also want a 1.5x1.25" bushing for the top of the bulkhead for the standpipe and you'll still want to reduce the drain pipe size to 1" for best results.

A good tip when building a standpipe is to make it taller than you need and then trim the base of the pipe to fit after it's built.
Reply With Quote
  #6  
Old 12-14-2010, 02:15 PM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

Quote:
Quote:
Originally Posted by Lampshade
A cheater way is to not use a bulkhead.... if you get a male threaded 1.5" PVC fitting, a flemale one and a soft O-Ring you can make a bulkhead out of it pretty easy. Cut the female threaded fitting off to use it as a tightening nut, and now you have a 1.5" PVC fitting in a 1.5" hole. 1.5" can flow 1200+GPH pretty easy, I was getting 1200+ on mine when it was duroso, now much more as herbie. Specs say 1600GPH, with gravity feed.

not sure i understand what you said at all lol im a newbie with plumbing and this is my first tank with a sump, it was all pre-plumbed, drilled etc. im just trying to make it less noisy.
generally people use bulkheads that look like this:


What you can do is use this male adapter:


and make a nut for it by cutting a female adapter off at the threads:


You will need a seal still, so using the seal from a bulkhead, or finding one in a hardware store works fine.


The only reason to do this is to get a little bit extra flow through a smaller hole. With a bulkhead you are inserting a bulkhead into the hole, then a pipe into the bulkhead, this reduces the hole size that water actually flows through.
__________________
My 150 In Wall Build
Reply With Quote
  #7  
Old 12-14-2010, 02:56 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

I'd stick with using a bulkhead.
Reply With Quote
  #8  
Old 12-14-2010, 05:28 PM
Magma Magma is offline
Member
 
Join Date: Oct 2010
Location: Calgary, AB
Posts: 341
Magma is on a distinguished road
Default

making a stockman pipe right now...let you know how it turns out..

Just hate that I had to buy a full 10ft stick of 1.5" PVC just to use 20" or less
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 05:36 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.