#28
|
|||||
|
|||||
![]() At my old house I ran RO/DI to my tank top off valve full time but because the run from the laundry room to the tank was large, I had it fill a reservoir in behind my tank and the tank topoff was filled from that reservoir. The RO/DI was on all the time into this reservoir but because it was so far away (well 20' or so) from the filters, it buffered things just enough that I ran this way without problems for years.
Then I moved and now had a tank 5' away from my water source so I removed the inline reservoir and had the RO/DI direct to the sump. What a mistake that was. I ended up replacing my RO membrane 3 times that first year before I figured out that the problem now was the incessant cycling of the membrane. It would literally run for about 5 seconds every 5 minutes. Turns out this is bad for a membrane. Who knew! So now what I do is run my RO/DI into a reservoir which then feeds my topoff downstream. I worry about filling up the reservoir maybe once every two weeks or so - I let it empty, or get near-to-empty, then I fill it to the top (letting the float valve shut the RO/DI off when it's full to prevent overflows). Since switching to this method I seem get about 2-3 years out of a membrane before I start noticing TDS creep that doesn't clear itself with an extra long flush. It's really the same thing as what a pressure tank does except instead of using a pressure based diaphragm to control the fill, I just open or close a valve to fill the reservoir in one big fill. Quote:
Quote:
Quote:
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! Last edited by Delphinus; 10-25-2010 at 08:38 PM. |