![]() |
|
#1
|
|||||
|
|||||
![]() Holy heck ron thanks alot the 400 w that isnt a problem sinceI use to have 250's over my tank the tank, houses Aussie Acans & LPS and 3 clams squamosa 10", 8" 5".
what is the average price of LEd's the cool white and Royal blue ron , is thee another place that you can get them from other then led supply.
__________________
180 starfire front, LPS, millipora Doesn't matter how much you have been reading until you take the plunge. You don't know as much as you think. |
#2
|
|||||
|
|||||
![]() Quote:
LEDs run USD $5 to $6 each mounted on stars. You could try nanotuners.com and see if they can give you a good deal on LEDs, drivers, optics etc as a large package deal? Some people really like Cutter Electronics in Australia or also ETG Tech in the US for larger buys. Quote:
That reefcentral article is okay but the problem is that he simply changed optics and did not adjust LED spacing. The two have to go hand in hand. If you go narrower optics for greater penetration of light into deeper tanks you need to space the LEDs closer together to get additive PAR. His results are not surprising given the way he did it. The conclusion is that for the spacing of LEDs he used 70 degree optics are best at the particular distance he measure PAR. If he had spaced the LEDs closer together and used tighter optics he would have likely seen higher PAR. This was not a scientific study that can generally be applied to all LED setups, only to those particular strips he used at the depth he measured. |
#3
|
|||||
|
|||||
![]() So Ron you have 20 LEd's for each row of 48" right and how many rows did you do my tank is 24 wide.
__________________
180 starfire front, LPS, millipora Doesn't matter how much you have been reading until you take the plunge. You don't know as much as you think. Last edited by Skimmerking; 10-07-2010 at 05:28 PM. |
#4
|
|||||
|
|||||
![]() I have 4 rows for my 18" wide tank. So ideally you would want 6 rows. But since you a doing LPS etc. rather then SPS as I have you may get away with 5 rows. If you want the ability to have higher PAR for SPS in the future then go 6 rows.
|
#5
|
|||||
|
|||||
![]() SO for a 60 " tank Ron would you say that
5 rows of 3W LED's with 60 optic's of 25 would do a 60" tank LIKE THIS * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * So 125 LEd's would all i need for my tank then and how many driver's or transformer 4 of them. the dimmable ones
__________________
180 starfire front, LPS, millipora Doesn't matter how much you have been reading until you take the plunge. You don't know as much as you think. Last edited by Skimmerking; 10-07-2010 at 06:38 PM. |
#6
|
|||||
|
|||||
![]() Yes, that looks right to me. How many drivers you need depends on what you are using. If you go with the Meanwell ELN-48 then you will need 10 of them, 5 for white and 5 for blue.
|
#7
|
|||||
|
|||||
![]() Actually, you want to stagger the white and blue so like this:
B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B W B |
#8
|
|||||
|
|||||
![]() Quote:
65 whites 65 royal blues with 60 degree optics and 10 meanwell eln-48 dimmable drivers and for a sheet of metal it should be alum heat shields what did you use ron
__________________
180 starfire front, LPS, millipora Doesn't matter how much you have been reading until you take the plunge. You don't know as much as you think. |