#1
|
|||||
|
|||||
![]() At 40 pse, my 90 gpd spectrapure takes about 20-25 minutes to produce a gallon. Warming the source water a bit will hep a bit
__________________
-captainhemo |
#2
|
||||
|
||||
![]() You have to remember, 100 gal per day is about equal to 4 gals per hour. or 1 gal per 15 min. So you are very close to what you should have.
As said, warming the incomming water and increasing city water pressure will help to bring up your volume of RO\DI. So will a permeate pump. How big is your accumulater ? |
#3
|
|||||
|
|||||
![]() heating the water doesnt mean using hot water. I believe hot water kills the membrane
whats your TDS out of the tap? Whats the pressure before the RO/DI unit and whats the pressure before the membrane? if you dont have pressure thing, you can get a pressure meter from homoe depot and throw a T on it wherever you need to measure at. Should be at 80psi from tap, around 60 before membrane. TDS is high, you have good water going into the drain and bad water coming out of the hose. So you have the waste and good water backwards If pressure at tap is low then you need to increase it If pressure right before the membrane is low then your carbon and sediment filters are old Last edited by Milad; 09-17-2010 at 10:57 PM. |
#4
|
|||||
|
|||||
![]() That sounds a little slow to me, it could be due to in-coming water temp./pressure etc. Adding a booster pump will increase production dramatically. Either way good to hear you are going to use RO water.
__________________
M2CW |
#5
|
|||||
|
|||||
![]() I guess with the accumulator tank I figured when I turned on the tap I would have 2 gallons on hand. I used a line saddle and pierced the 1/4 line between the shutoff and the tap. I'm thinking of changing out the line and t'ing it off so I have better flow. I also think i'm going to have to put in a holding tank on a float valve.....just where to put it
__________________
Murray I reserve the right to hijack any thread I want to!! My carbon footprint is bigger than your carbon footprint !!!! |
#6
|
|||||
|
|||||
![]() Have the 100gpd Aquasafe fills a 20g container overnight (8-10 hrs).
You'll find quite the roll off in rate with anything less than the membranes spec'd temp and pressure. Here's a calculator
__________________
my tank |
#7
|
||||
|
||||
![]() i have the same unit and my water pressure is pitiful............it takes about 15 hrs to get 20G
__________________
250G DD LED SPS R.I.P. 180G LED SPS 80"x36". 300G custom build Owner of Mountain Ridge Heating and Gas Class A gas fitter, HVAC |