I don't know much about the technical aspect of GFIC's but I do know that when I noticed my power head in my tank wasn't working I saw that the GFIC had been tripped. So I unplugged the cord, reset the GFIC and then plugged the cord back in again, and again it tripped the GFIC, the breaker the GFIC was on never tripped, it only tripped the GFIC.

When I finally looked back behind the tank and examined the power cord, much to my shock this is what I found:





All I have to say is thank God that the GFIC tripped, because the breaker it was on never did. Also very thankful that the only thing that got fried was the power cord and power head. I'm guessing water splashed out of the tank and onto the extension cord, causing a small electrical fire (which you can see the damage done to the cords in the above pic.'s) causing the GFIC to trip. Needless to say IMO if the GFIC hadn't tripped (or if I didn't have one) I'm guessing the damage would of been a lot worse!
__________________
One more fish should be ok?, right!!! - Laurie

Last edited by fishoholic; 08-07-2010 at 04:20 PM.
Reply With Quote
  #2  
Old 08-05-2010, 03:43 PM
globaldesigns's Avatar
globaldesigns globaldesigns is offline
Member
 
Join Date: Mar 2008
Location: Calgary, AB
Posts: 1,863
globaldesigns is on a distinguished road
Default

Quote:
Originally Posted by RR37 View Post
I think you missed the point,

GFI = GOOD

AFCI or FUSE = GOOD

Using both = DOUBLE GOOD

Not knocking a GFCI I think the are a necessity. Anyone not having one should think about getting one. While you are doing the GFI, look into fusing your system somehow. Claiming they will prevent fire is a false sense of security, A GFI will prevent unwanted shock and electrocution, seeing as that is all they were designed to do. ( In a situation where a fault in grounding is present )

There are any number of reasons why your power-strip is charred, not having a surge protector, circuit overloading, missing internal circuit breaker, power strip daisy chaining, plugging addition items into the duplex outlet, repeated moisture damage, to name a few. In any event all of the things listed will go unnoticed by the GFI, they are only there for ground faults. Please do not attempt to inform people otherwise, your logic is flawed. Its not a matter of opinion, its a static right/wrong.

Don't mean to come off harsh. Just happens that way.
No problemo, I will play nicely in your sand box. HEHE...

Thanks for the advice on the AFCI, this looks like something you add beside the normal breaker in your breaker box? If so, again thanks, I will research this more.
__________________



Setup: 180G DT, 105G Refuge (approx. 300lbs LR, 150lbs Aragonite)
Hardware: Super Reef Octopus SSS-3000, Tunze ATO, Mag 18 return, 2x MP40W, 2X Koralia 4's Wavemaker
Lighting: 5ft Hamilton Belize Sun (2x250W MH, 2X80W T5HO)
Type of Aquarium: mixed reef (SPS & LPS) with fish
Dosing: Mg, Ca, Alk
Reply With Quote
  #3  
Old 08-05-2010, 11:18 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by globaldesigns View Post
No problemo, I will play nicely in your sand box. HEHE...

Thanks for the advice on the AFCI, this looks like something you add beside the normal breaker in your breaker box? If so, again thanks, I will research this more.
They are code in some places for bathrooms and bedrooms. All mine are on them. They replace the standard breakers. I have posted pics of them a couple times now. Latest is here,


http://www.canreef.com/vbulletin/sho...+storms&page=3
__________________
Doug
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:36 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.