Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 07-17-2010, 04:01 PM
SAMSHUNG's Avatar
SAMSHUNG SAMSHUNG is offline
Member
 
Join Date: May 2010
Location: Vancouver
Posts: 51
SAMSHUNG is on a distinguished road
Default

EPIC-ness!!!

(subscribing the s#it out of this thread.)
Reply With Quote
  #2  
Old 07-17-2010, 06:32 PM
andestang's Avatar
andestang andestang is offline
Member
 
Join Date: Sep 2002
Location: Okotoks
Posts: 1,053
andestang is on a distinguished road
Default

Looking supreme ! Is that glass covering your overflow box ? You must of enjoyed having it built at home, seeing the whole thing come together. That's also up my sleeve.
__________________
Mike

150g reef, 55g sump, T5's, Vertech 200A, Profilux III - German made is highly over rated, should just say Gerpan made.

Reefkeeper - individual obsessed with placing disturbing amounts of electricity and seawater in close proximity for the purpose of maintaining live coral reef organisms.
Reply With Quote
  #3  
Old 07-19-2010, 12:12 AM
abcha0s's Avatar
abcha0s abcha0s is offline
Member
 
Join Date: Jan 2010
Location: Calgary
Posts: 545
abcha0s is on a distinguished road
Default

<New Content Posted>

Planning the ATO (Automatic Top Off)..........<moved to 38 - Changed status to draft>

Pretext: I’ve had my ATO fail while on holidays. This caused the sump return chamber to completely evaporate leading to a subsequent failure of the return pump. After fixing the ATO and replacing the return pump, the ATO did what it was supposed to do and pumped 10 gallons of saturated Kalk water (pH 12.4) back into the system. The result was a pH spike reaching upwards of 9.5. While I was able to recover from this without a tank crash and better yet, without losing any wildlife, it drove home the importance of a reliable ATO. In my opinion, it is one of the more critical components and can potentially fail without warning.

Last edited by abcha0s; 02-15-2011 at 05:38 PM.
Reply With Quote
  #4  
Old 07-19-2010, 01:24 AM
steveg steveg is offline
Member
 
Join Date: Mar 2009
Location: calgary
Posts: 52
steveg is on a distinguished road
Default Wow!!!!!!!!!

Amazing how a quick look on the computer can generate such green eyed monster feelings................:mrgreen :

Looking forward to seeing this develop!
Reply With Quote
  #5  
Old 07-19-2010, 01:30 AM
TheMikey's Avatar
TheMikey TheMikey is offline
Member
 
Join Date: Sep 2008
Location: Saskatoon
Posts: 257
TheMikey is on a distinguished road
Default

Absolutely fantastic build. The level of detail and planning incorpotated into the build (as well as the great explanations) could (should?!) be made into a How-To for those looking at building large tanks. You seem to have all your bases covered on your build.

I do have one question, however:

In regards to the steel design (and redesign) I've noticed that on the stand that the aquarium isn't actually sitting on the back brace where you've added the additional support and the entire backside seems to be for the benefit of the overflow alone. You were very concerned in this build early on about having enough support but from my (rather limited, forgive me) knowledge it seems like you are ignoring the rear re-enforcement entirely. Can you give me the rationale for it?

I really hope this doesn't come off as a flame/troll post (it's not I assure you ) I just found it a little odd the way the tank fits on the stand.

Again, fantastic tank journal; it's making me itch for an upgrade
Reply With Quote
  #6  
Old 07-19-2010, 02:29 AM
abcha0s's Avatar
abcha0s abcha0s is offline
Member
 
Join Date: Jan 2010
Location: Calgary
Posts: 545
abcha0s is on a distinguished road
Default

Quote:
Originally Posted by TheMikey View Post
Absolutely fantastic build. The level of detail and planning incorpotated into the build (as well as the great explanations) could (should?!) be made into a How-To for those looking at building large tanks. You seem to have all your bases covered on your build.

I do have one question, however:

In regards to the steel design (and redesign) I've noticed that on the stand that the aquarium isn't actually sitting on the back brace where you've added the additional support and the entire backside seems to be for the benefit of the overflow alone. You were very concerned in this build early on about having enough support but from my (rather limited, forgive me) knowledge it seems like you are ignoring the rear re-enforcement entirely. Can you give me the rationale for it?

I really hope this doesn't come off as a flame/troll post (it's not I assure you ) I just found it a little odd the way the tank fits on the stand.

Again, fantastic tank journal; it's making me itch for an upgrade
Hey Mikey

Sure - ask me a difficult question.

There are a couple of ways to look at this. Let's make sure we are talking about the same thing.



I believe that you are referring to the fact that the tank sits on Beam B and not Beam A. I did consider this.

The first modification I made to support this arrangement was to add an additional brace from front to back. Where splitting the load in two squares (3'x3') should be sufficient, I am splitting the load in three rectangles (3'x2').

I also figure that the two beams together, being only 2.5" apart and welded in 4 places, will collectively have a strength greater than a single beam.

Finally, I am counting on the distance to the braced beam (Beam A) being small enough that the load will be almost directly transfered between the two beams.

Having said all of that - there's not a lot of science behind it. It's more intuition than anything. If the stand weren't overbuilt, I would be a little more concerned, but I think there is a sufficient safety variable built in to offset the risk of deflection along this beam.

This stand design gives me considerably more space underneath the tank. The extra 4.5" makes a big difference. It also will make it easier to hide some of the plumbing when I start panneling the stand. So far, I don't regret the design.

Anyway, the question is perfectly reasonable, no need to appologize.

- Thanks
Reply With Quote
  #7  
Old 07-19-2010, 02:38 AM
abcha0s's Avatar
abcha0s abcha0s is offline
Member
 
Join Date: Jan 2010
Location: Calgary
Posts: 545
abcha0s is on a distinguished road
Default

Quote:
Originally Posted by andestang View Post
Looking supreme ! Is that glass covering your overflow box ? You must of enjoyed having it built at home, seeing the whole thing come together. That's also up my sleeve.
Thanks!!

There is a glass cover for the overflow. It is removable and is primarily there for looks. There may also be a secondary benifit of noise reduction making a quiet overflow almost silent

One note if you are considering something similar. Glass on glass scratches and chips. I will put little rubber feet (matching the silicone thickness) to ensure that the pieces never touch. I considered an acrylic cover, but 15mm acrylic is either very difficult to find, or just not manufactured.

Watching the build was a lot of fun. Can't wait to see yours.

BTW - If you wan't to come check out the tank before you finalize your plans, just let me know.
Reply With Quote
  #8  
Old 07-19-2010, 03:18 AM
DiverDude's Avatar
DiverDude DiverDude is offline
Member
 
Join Date: Feb 2010
Location: Calgary
Posts: 519
DiverDude is on a distinguished road
Default

Quote:
Originally Posted by abcha0s View Post
...Watching the build was a lot of fun.
The voyeur in me wonders if perhaps you happened to video the assembly of the tank.

That would be....awesome
__________________
-Mark

29 Gal Bowfront w/24" LED Lights. DIY HOB Sump (5.4 Gal) MP40. Orange Spotted Watchman Goby, 2 Clownfish and a few hermits.
Reply With Quote
  #9  
Old 07-19-2010, 03:27 AM
lastlight's Avatar
lastlight lastlight is offline
Gold Member
 
Join Date: Jan 2006
Location: Calgary
Posts: 6,997
lastlight has a spectacular aura aboutlastlight has a spectacular aura aboutlastlight has a spectacular aura about
Default

When Gary built my old 400 on-site there was a strange smoke/fog surrounding him. The shroud of mystery if you will. Try as I did I could not directly view the magic that is the on-site build.

Actually...I just felt he wanted some privacy and I let him be =)
__________________
Brett
My 67 392 225 101 94 34 97 404 28 93 209 gallon reef.
Reply With Quote
  #10  
Old 07-19-2010, 06:12 AM
andestang's Avatar
andestang andestang is offline
Member
 
Join Date: Sep 2002
Location: Okotoks
Posts: 1,053
andestang is on a distinguished road
Default

I may just have to do that, thanks.



Quote:
Originally Posted by abcha0s View Post
BTW - If you wan't to come check out the tank before you finalize your plans, just let me know.
__________________
Mike

150g reef, 55g sump, T5's, Vertech 200A, Profilux III - German made is highly over rated, should just say Gerpan made.

Reefkeeper - individual obsessed with placing disturbing amounts of electricity and seawater in close proximity for the purpose of maintaining live coral reef organisms.
Reply With Quote
Reply

Tags
custom tank, deep dimension, high end, redundant, reef


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:31 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.