![]() Here is example of my other idea
I think I actually like this one. But im sure someone will find a flaw. I could have it higher up the overflow box too. ![]() |
#2
|
|||||
|
|||||
![]() This idea has an serious reverse siphon potential. You would be 100% dependent on somehow breaking the reverse siphon with a check valve or some other method....otherwise you would drain your tank into the sump during a power failure.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436 |
#3
|
|||||
|
|||||
![]() Could I just not have a couple holes in the pipe at the top of the tank to break the siphon? or is it because it goes so far down that the holes wont work.
|
#4
|
|||||
|
|||||
![]() What will stop water from spraying out the holes when the pump is on or am I miss understanding something?
|
#5
|
|||||
|
|||||
![]() when the pump is on, the holes are jsut under the water, when the pump is off the holes will be above the water
|
#6
|
|||||
|
|||||
![]() Quote:
Quote:
Sure..that will work. As will a check valve. Put both in place. I'm just saying that I would not want to be THAT dependent on those working...because if they fail during a power outage you are talking about complete death of the tank and flood damage to your house. The holes WILL plug up. You'll need to keep those cleaned out all the time. Check valves get stuck open. Especially if they don't get exercised much. My returns go over the top edge of the aquarium and exit only 2" below water line. Even if my check valve fails, there is no way I can siphon more than 2" of water from the tank. Design to be fail proof. You'll sleep better.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436 |
#7
|
|||||
|
|||||
![]() I would like to second the check-valve suckage thing... although I would like to say that please dont even design a system that uses or relies on one. IMO, and in my experience... they totally suck. MOST check valves (have seen many diff brands in action) fail. Stuff either gums up in them or the 'flap' if its rubberized 'gives out' or gets deformed into the 'open' shape.
Some are around that almost surely will not fail, but for me, thats not good enough. Why not simply design a system that doesn't worry about one, and simply takes care of itself hassle free, 100% guarenteed not to leak, and saves you the money of buying one. Just my opinion. (You can certainly include one if you want, but in a well-designed system, it wont be necessary).
__________________
No more tanks ![]() Cheers, Chris |
#8
|
|||||
|
|||||
![]() damn you untamed and your knowledge
I rejigged it and put it 2 inches below the water level for my tank it would be 15gallons if the holes pluged and the check valve jammed I also changed out the tunze 6205 for two tunze 6105s Watcha guys think? ![]() |