#1
|
||||
|
||||
![]() ok here it is
Here is the screenshot of the second tank HEre is the overflow box of this tank Here is the back of the tank Water is draining into the sump The return line from the sump ok here it is Here is the screenshot of the second tank HEre is the overflow box of this tank Here is the back of the tank Water is draining into the sump The return line from the sump I have put some thoughts into what Tony said in the thread, my drain does bend 90 degree and it has to travel horizontal from the ground into the sump. Thus it possible that the air got trapped inside the flexible pipe, eventually it build up enough that stop water from flowing back to the sump thus causing water overflow in my tank. After a 20 minutes or so (my assumption) it has enough pressure to push the air through and back to normal level but by then i got a wet floor already. Do you think my hypothesis is right? I have reduce the flow of my return line but if my hypothesis is right then it is a ticking bomb Last edited by Coleus; 03-27-2010 at 08:31 PM. |
#2
|
||||
|
||||
![]() your return pump is pushing more water back to the tank than the drain can handle chock the return pump by using a ball valve. then you can adjust the flow additional flow in the tank should be done with power heads.
Bill |
#3
|
|||||
|
|||||
![]() K so I see that you already have a ball valve in the return line from the sump to choke back the pump if necessary.....try to make sure that all drain and return lines are running at a gradual down slope towards the sump, no ups and downs in the lines for air locks. umm for your drain line to the sump, if there are any 90's in the lines try to see if you can switch to 45 degree elbows instead so that water flow doesnt get slowed down too much on the way from tank to sump....also I noticed that you are using 1/2 hose for the return line when there is a 1 inch return bulkhead soo im wondering if you ended up doing the same on the return line. Did you take that 1 1/2 inch bulkhead there and slap a 1 inch hose on it for the drain? if so....dont, try to get some plumbing that matches the 1 1/2 inch bulkhead for the drain so that way you have maximum flow rate available to you for the drain. Your return line is fine for the way the hoses are except the one bend in the hose there, but the drain line may need some work on it.
__________________
Current System 75 Gal with 30 Gal Sump Reef Past Tanks 60 Gallon True Cube 30 Gallon Breeder 165 Eurobraced Starfire Custom 10 Gallon Softy Tank(My First Tank) Last edited by bauder1986; 03-27-2010 at 08:52 PM. |
#4
|
||||
|
||||
![]() Quote:
what do i have to do so that the air does not get trapped? Make sure the water does not travel upward for return line? Well, I don't want to get out of this hobby but thinking of shutting down this tank. It causes me so much grief from beginning |
#5
|
||||
|
||||
![]() try plumbing everything in pvc-i don't like the look of your return line-no clamp to hold your line-i also think it would be better not to have ridges in your line.i agree with using 45s instead of 90s
|
#6
|
|||||
|
|||||
![]() K so I see that you already have a ball valve in the return line from the sump to choke back the pump if necessary.....try to make sure that all drain and return lines are running at a gradual down slope towards the sump, no ups and downs in the lines for air locks. umm for your drain line to the sump, if there are any 90's in the lines try to see if you can switch to 45 degree elbows instead so that water flow doesnt get slowed down too much on the way from tank to sump....also I noticed that you are using 1/2 hose for the return line when there is a 1 inch return bulkhead soo im wondering if you ended up doing the same on the return line. Did you take that 1 1/2 inch bulkhead there and slap a 1 inch hose on it for the drain? if so....dont, try to get some plumbing that matches the 1 1/2 inch bulkhead for the drain so that way you have maximum flow rate available to you for the drain. Your return line is fine for the way the hoses are except the one bend in the hose there, but the drain line may need some work on it.
__________________
Current System 75 Gal with 30 Gal Sump Reef Past Tanks 60 Gallon True Cube 30 Gallon Breeder 165 Eurobraced Starfire Custom 10 Gallon Softy Tank(My First Tank) |
#7
|
||||
|
||||
![]() Thanks for everyone inputs but sadly i have to shut down this tank. *Sigh*
|
#8
|
||||
|
||||
![]() I have the ball valve so i already reduced the flow and use power head to get more flow. But the one thing i don't understand is i never got a chance to witness this happen. It happens like 20 minutes and then it back to normal
|