![]() |
|
#1
|
|||||
|
|||||
![]() Quote:
The primary drain is created by the 2" pipe. Water flows in between the 2" and 1.25" pipe and then through the gate valve. The gate valve is used to match the flow rate to the return pump and adjust the water level in the overflow box to just below the top of the 1.25" pipe. It's just like a standard herbie but the back up drain is inside the primary. Make sense? |
#2
|
|||||
|
|||||
![]() Quote:
Cool, thats definitely something to investigate further. Thanks for the info!! ![]()
__________________
Christy's Reef Blog My 180 Build Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free. |
#3
|
|||||
|
|||||
![]() What an ingenious little bit of plumbing! I have 2 holes in each overflow, so I don't need it personally, but I think a link to that should almost be a sticky somewhere.
One thing I was thinking. What about eliminating the 2" standpipe inside the overflow. This should increase the flow potential and reduce detritus buildup in the overflow... just a thought. |
#5
|
|||||
|
|||||
![]() The cross sectional area between the 2" and the 1.25" pipe is very close to the area of a 1.25" pipe. So both the primary and secondary should each be capable of flowing what is typical for a 1.25" drain.
|
#6
|
|||||
|
|||||
![]() Christy I have some 2" here but not much, your welcome to it. How much do you need? Home Hardware etc. all sell it by the foot.
|
#7
|
|||||
|
|||||
![]() Quote:
![]() ![]() I need about 4 feet I think.
__________________
Christy's Reef Blog My 180 Build Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free. |
#8
|
|||||
|
|||||
![]() Christy,
You guys have an Andrew Sheret in Nanaimo. They should have anything you'd need. But they won't sell you pipe by the foot. Here's the address: 2545 McCULLOUGH ROAD
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#9
|
|||||
|
|||||
![]() If you did this then the full overflow box would drain when the flow is shut off, not always a good thing unless you have the sump volume, but an option for sure.
|