Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > Regional Forums > British Columbia

Reply
 
Thread Tools Display Modes
  #1  
Old 11-14-2009, 04:31 PM
Jason McK's Avatar
Jason McK Jason McK is offline
Member
 
Join Date: Mar 2003
Location: Ladner,BC
Posts: 3,032
Jason McK is on a distinguished road
Default

Well I ordered a new ASOV form Aquasafe and WOW I recieved my order the next day. Service was amazing.

Despite the new Valve it still does not shut off.

Any other suggestions?
__________________
My old Tank Shut down Jan 2011
New 220G build about to start
Reply With Quote
  #2  
Old 11-16-2009, 05:12 AM
hillegom hillegom is offline
Member
 
Join Date: Nov 2008
Location: Surrey
Posts: 1,998
hillegom is on a distinguished road
Default

I'd say check all the plumbing against that melev's site's schematic.
The ASOV is just that. It shuts off the flow. Its either the plumbing or the new valve is faulty. Check the plumbing to and from the ASOV

Last edited by hillegom; 11-16-2009 at 05:26 AM. Reason: addition
Reply With Quote
  #3  
Old 01-12-2010, 11:00 AM
piusma piusma is offline
Junior Member
 
Join Date: Dec 2008
Location: Richmond
Posts: 23
piusma is on a distinguished road
Default

I realized this is an old thread but I'd like to bring this up and may be someday it'll help one of the members. I have the same problem with the auto shut off valve not working properly. It'll slow the flow and may be stop for a second or two and it'll go again. If you have not installed the pressure tank, it will not work properly. At least mine doesn't without the pressure tank. Try reinstalling your pressure tank if you have removed it and it should solve the problem.
Steven
Reply With Quote
  #4  
Old 01-12-2010, 05:52 PM
mike31154's Avatar
mike31154 mike31154 is offline
Member
 
Join Date: Jul 2008
Location: Vernon
Posts: 2,073
mike31154 will become famous soon enough
Default

Thanks for that info re the pressure tank. I don't have a pressure tank on my system and the ASOV has never worked since day 1 so I've always done what lastlight does, keep an eye on the system and manually shut it down. Took it apart to have a look and still no joy when I reassembled it. Pretty simple really, just a diaphragm that should close the openings on one side with sufficient backpressure, so apparently not much that should go wrong. But due to my own experience with it, I would never trust that thing on it's own without being monitored. I think I may have got it to work a couple of times by cycling the membrane flush valve, but certainly not reliably. Maybe I'll try adding a pressure tank for RO at some point to see if that helps.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206

Last edited by mike31154; 01-12-2010 at 05:55 PM.
Reply With Quote
  #5  
Old 01-12-2010, 07:00 PM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

mines system is back up 100%, seemed the reason for not shutting off was indeed the check valve (not the ASOV)
__________________
my tank
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 05:34 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.