I think as long as you wire it properly with marettes or electrician's tape that there wouldn't be any issues. You will probably have to buy some wire to make the connections longer. I've been thinking of doing this to my GLO and my Degenbao fixture as well so I can make external ballasts.
__________________
~ Mindy

SPS fanatic.

Reply With Quote
  #2  
Old 08-10-2009, 03:57 PM
mike31154's Avatar
mike31154 mike31154 is offline
Member
 
Join Date: Jul 2008
Location: Vernon
Posts: 2,073
mike31154 will become famous soon enough
Default

I dismantled my two lamp 36" GLO a while back so I could use the reflector for 2 MH lamps that I ghettoed up over my tank. Didn't take any photos unfortunately. The ballast is quite long & narrow and as Myka mentioned you can mount it externally (or in a hood) no problem as long as you use safe wiring practices. This includes grounding the metal case of the ballast. You'll see that the grounding wire for the ballast is screwed to the housing, just use the same wire and attach it to a good ground when you wire up the retro.

The other thing to watch for is the distance from ballast to lamp, you don't want to extend that too far since not all ballasts are designed for 'remote' mounting, they may have trouble firing the lamps. If you do need to extend the wiring, make sure it's at least 18 guage, solid wire, not stranded. IIRC, I popped the top off the ballast casing and it was completely potted inside, that is all the components are sealed in 'tar' so it's quite water resistant. Don't think a box is required for the ballast, just make sure the case is grounded and the top is secured so it doesn't fall off. If you don't pop it off like I did, it should be fine. You'll need to stick to the same size & number of lamps too, don't try to add another lamp or use a 48 if your GLO is a 36.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206

Last edited by mike31154; 08-10-2009 at 04:00 PM.
Reply With Quote
  #3  
Old 08-10-2009, 07:58 PM
ElGuappo's Avatar
ElGuappo ElGuappo is offline
Member
 
Join Date: Feb 2008
Location: Calgary, Ab
Posts: 1,593
ElGuappo is on a distinguished road
Default

great thanks
__________________
72 Gallon Bowfront Reef.. Hardware:2x250w Luminex Elite HQI Reflectors (Phoenix Hexarc Bulbs), Galaxy 2x250w Electronic ballast, Euroreef 130 Skimmer, Sedra KSP 7000 Retern... Live Stock: Pair of Hawaiian Flame Wrasse, Leopard Wrasse, Pink Streaked Wrasse, Pair True Percula Clowns, Potters Angel, African Flameback Angel, Orange Fin Tomini Tang, Yellow Assessor, Tailspot Blenny, Purple Firefish..

45 G FW Asain Barb Community tank.

Reply With Quote
  #4  
Old 09-05-2009, 02:28 PM
vic622's Avatar
vic622 vic622 is offline
Member
 
Join Date: Jan 2009
Location: Ottawa, ON
Posts: 144
vic622 is on a distinguished road
Default

This makes good sense, but if the retro is going into a wood stand (either for the top or below the tank for the fuge) what should you use for a ground?
Vic

Quote:
Originally Posted by mike31154 View Post
... This includes grounding the metal case of the ballast. You'll see that the grounding wire for the ballast is screwed to the housing, just use the same wire and attach it to a good ground when you wire up the retro.
... Don't think a box is required for the ballast, just make sure the case is grounded ...
__________________
~ Vic ~

75gal Reef
35 gal sump/fuge ~ about to move all to new condo!


Ottawa Tank Build
My 1st Reef Tank Build
Reply With Quote
  #5  
Old 09-05-2009, 02:45 PM
intarsiabox intarsiabox is offline
Member
 
Join Date: May 2009
Location: Sherwood Park
Posts: 1,419
intarsiabox is on a distinguished road
Default

The ballast is grounded through the plug but if you want extra protection just get a 3 prong plug and 3 wire cable (white, black, green) and connect the ground wire from your ballast to the ground in the cable. To make the wire to wire connections secure and not bulky I would solder them together and shrink wrap them then they will never come undone. You also have a guaranteed connection and the new connection is only a little fatter than the wires themselves. If you need to increase the length of the wires the heavier the gauge the less voltage drop of there is.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:35 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.