Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #11  
Old 04-22-2009, 11:11 PM
Trigger Man Trigger Man is offline
Member
 
Join Date: Sep 2008
Location: Calgary, Alberta
Posts: 802
Trigger Man is on a distinguished road
Default

Quote:
Originally Posted by Doug View Post
Ha, trying to grow sps under T-5 lighting. Now thats a joke.

http://reefcentral.com/forums/showth...5&pagenumber=1

I usually dont like linking another forum but some outstanding sps aquariums in this thread. Not sure of the depths without reading it again but some I know for sure are that deep or close to it.
Great link, I never understand why people are so stuck on their ways on this topic. It has been proven time and time again that T5's can grow great thriving SPS tanks, yet somehow all those pictures of it occurring seem to miss MH users. I guess it took a long time for people to start believing the earth was not square, even after all the ship explorations and date that said it was circular.

As Lorenz0 said "canreef [and many of the other forums are] dominated by people who believe that MH is the only way to go. IMO MH is good for growing but color is a whole different story. Still can NOT get the same colors that you can with T5's (edit) unless you run 22k MH but than your losing your growth

Its all up to you really, personally i prefer T5's and will never own MH.... but the temptation has been there to try them out"

I feel the same way about T5's.
__________________
RSM 250. Clownfish, Fox face, Blue tang, Yellow tang, Kole tang, Clown tang, Coral beauty angel, French Angel, splendid dottyback. CUC, softies, lps, sps.
Reply With Quote
  #12  
Old 04-22-2009, 11:15 PM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

I'm doing the mix as well. The 2x250w MH for the PAR, supplemented with T5s to help with the colours and that dusk/dawn thing. Some comparison pictures here.
Reply With Quote
  #13  
Old 04-22-2009, 11:43 PM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by Myka View Post
Another issue with lighting that many many people fail to consider is water clarity. There are many reasons for higher or lower water clarity, and generally people with less experience are less likely to have high water clarity. This HUGELY affects the amount of light penetration, and is not as easy to achieve as you may think.
Very good answer, the differance in PAR will be a little more at 24" though, more like 50 to 100% more depending on reflectors and such.

only thing I am interject into this is water clarity makes way less differance than people think. unless the water is so cloudy you notice it and have a hazy look to it, you are going to get less than 1% atinuation in a 24" deep tank, once there is a slight haze you get about 1 to 2% and if you can't see the back of the tank clearly then it gets bad. the only reason I know this is when my tank crashed due to a crapy heater I figured I would take something good out of it and did PAR readings at various stages of clarity. Had to get something good out of loosing over 7K replacment value in corals Also glass tops only make a differance of about 3% for 1/4" glass. acrylic would be less.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote
  #14  
Old 04-22-2009, 11:57 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

What fails to be mentioned many times when asking a question such as this thread, is the variety of T-5 fixtures.

Notice many of those, {not all mind you}, bulbs in that thread are over driven. Plus some of the fixtures are top end units. Thats a lot of difference when comparing what they will grow and depth penetration.

My 6 bulbs fixture is very good, IMO, but when it was on my 90, I think it may have not been enough for sps corals, except for higher up. But then its half the cost of the other units and with bulbs to boot. Try explaining that to lowballers when selling a unit like that. Sheez.

Anyways, I would not hesitate to use my unit on a 16in. high tank for sps corals. If I was doing a 24in deep tank and wished to run T-5,s I would use one of the high end fixtures, esp. the models that run the bulbs @ 80w or build my own and use the Icecap do it yourself kits. My friend has a 120g full blown sps tank that and it rivals any halide lit tank I have seen.

In defense of halides though, have a look at some of them in our featured section. Some blow your mind sps tanks there. When I look at my friend Mikes 5ft. tank running his three 250,s both 12K Reeflux and a centered 20k, there is no doubt in my mind thats part of the reason for the nice growth and outstanding colors in all his sps

So this basically says, more than one way to run the tank, just buy the correct product for your own needs.
__________________
Doug
Reply With Quote
  #15  
Old 04-23-2009, 02:57 AM
Snappy's Avatar
Snappy Snappy is offline
Member
 
Join Date: Jan 2005
Location: Calgary, Alberta
Posts: 4,675
Snappy is on a distinguished road
Default

My tank is 27" deep and I run a mixture of M/H & T5 and really like the combo. 5x 250w 14k, 2x 150w 20k & 12x 54w T5 bulb mix. It's the best of both worlds. Lot's of colour, growth and still get the MH shimmer.

Another point about the MH is: are they HQI or single end moguls because between the two of them there is little comparison IMO. HQI all the way!
__________________

Greg

Last edited by Snappy; 04-23-2009 at 03:01 AM.
Reply With Quote
  #16  
Old 04-23-2009, 04:07 AM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by Snappy View Post
Another point about the MH is: are they HQI or single end moguls because between the two of them there is little comparison IMO. HQI all the way!
ahh, here is another one I can dispell, it isn't the DE bulb that is better than the SE, b ut rather the HQI ballast that is better. A SE bulb on a HQI Ballast has both more par and coverage than a DE bulb on the same bulb.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote
  #17  
Old 04-23-2009, 04:14 AM
Canadian's Avatar
Canadian Canadian is offline
Member
 
Join Date: Oct 2001
Location: Victoria, BC
Posts: 619
Canadian is on a distinguished road
Default

T5 is only adequate for tanks 12" or less in depth. Anything greater than that depth and growth rate for SPS will be less than 1mm per month when using T5s.

Additionally, PAR values measured by meters such as the Apogee Quantum meter measure false high PAR values for actinic fluorescent lamps so the measured T5 PAR values are misreported (over inflated).
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets

"Mens sana in corpore sano"
Reply With Quote
  #18  
Old 04-23-2009, 06:00 AM
ickmagnet ickmagnet is offline
Member
 
Join Date: Apr 2009
Location: Surrey
Posts: 123
ickmagnet is on a distinguished road
Default

My tank is approx 30" deep and I am running T5s (8 tubes) and before this, i had MH lights (750 w). My soft corals and anemones are responding just fine to my T5s and I don't have to worry about crazy electricity bills.

I should note that most of my corals are closer to the top (about 2 feet away from light)
Reply With Quote
  #19  
Old 04-23-2009, 01:01 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by Canadian View Post
T5 is only adequate for tanks 12" or less in depth. Anything greater than that depth and growth rate for SPS will be less than 1mm per month when using T5s.

Additionally, PAR values measured by meters such as the Apogee Quantum meter measure false high PAR values for actinic fluorescent lamps so the measured T5 PAR values are misreported (over inflated).

So your saying all those in the thread I linked are wrong??
__________________
Doug
Reply With Quote
  #20  
Old 04-23-2009, 01:12 PM
fishytime's Avatar
fishytime fishytime is offline
Member
 
Join Date: Mar 2007
Location: E-town
Posts: 5,390
fishytime will become famous soon enough
Default

Quote:
Originally Posted by Doug View Post
So your saying all those in the thread I linked are wrong??
*ding ding ding* and in this corner
__________________
260g mixed reef, 105g sump, water blaster 7000 return, Bubble King SM 300 skimmer, Aqua Controller Jr, 4 radions, 3 Tunze 6055s,1 tunze 6065, 2 Vortech MP40s, Vortech MP20, Tunze ATO, GHL SA2 doser, 2 TLF reactors (1 carbon, 1 rowa). http://www.canreef.com/vbulletin/showthread.php?t=50034 . Tank Video here http://www.vimeo.com/2304609 and here http://www.vimeo.com/16591694
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 08:05 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.