Opps I was too late with my thoughts...
__________________
Robb
Reply With Quote
  #2  
Old 04-22-2009, 12:25 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

A Herbie standpipe potentially could flow more in that it's a siphon but then to create the Herbie you're restricting the flow with a valve to have the water back up over the top of the stand pipe.

Would think for estimating probably not to far off with the commonly used gravity flow rates (~600gph for the 1").
Reply With Quote
  #3  
Old 04-22-2009, 02:31 AM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Well we can dispute this forever but if you measure the pressure in the drain line (near the base) a Herbie will show a higher pressure than a Durso as no air will be in the line. A Durso may typically show close to atmospheric pressure while a Herbie will show a pressure equal to the height of the water above it. More pressure means a higher velocity and therefore more flow. How much more? Hard to say as it will totally depend on the setup. You can also eliminate most of the air from a Durso style drain if done correctly. Some people will see more dramatic results from a change over because their Durso style drain was never done correctly, while others don't notice anything.

The bottom line here however is that the main purpose of a Herbie style overflow is not more flow but rather noise and air bubble reduction. If you want more flow you should increase the pipe size or add a second drain, it really is as simple as that.
Reply With Quote
  #4  
Old 04-22-2009, 02:51 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

Hey I'm not arguing but seen on RC someone was figuring he could get 1000gph from a 1" drain, seemed a bit much.
Reply With Quote
  #5  
Old 04-22-2009, 04:10 AM
golf nut golf nut is offline
Member
 
Join Date: Feb 2004
Location: just north of Toronto
Posts: 454
golf nut is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
The bottom line here however is that the main purpose of a Herbie style overflow is not more flow but rather noise and air bubble reduction.
Exactly.
Reply With Quote
  #6  
Old 04-22-2009, 04:11 AM
golf nut golf nut is offline
Member
 
Join Date: Feb 2004
Location: just north of Toronto
Posts: 454
golf nut is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
If you want more flow you should increase the pipe size or add a second drain, it really is as simple as that.
And if you make the overflow the correct size there will be no noise and no need for a Durso.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:14 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.