![]() Quote:
Here are measured PAR values for various T5 lamps: http://tfivetesting.googlepages.com/par
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#2
|
|||||
|
|||||
![]() Steve,
Can you please explain how actinics produce "false high" PAR readings despite the fact that measured PAR values for actinic T5HO lamps are considerably lower than whiter lights? For example: ATI Sun Pro 357 Aquablue 336 Blue Plus 311 Actinic 137 How does that actinic lamp running at 137 PAR some how artificially create "false high" PAR readings when the measured PAR is less than other lamps surrounding it?
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" Last edited by Canadian; 04-01-2009 at 03:29 PM. |
#3
|
|||||
|
|||||
![]() Quote:
Steve
__________________
![]() Some strive to be perfect.... I just strive. Last edited by StirCrazy; 04-01-2009 at 11:24 PM. |
#4
|
|||||
|
|||||
![]() Ok, re read my stuff, between painting rooms.. I made a mistake, yes I know.. imigian that, not that it happens a lot but yes even I can make a mistake.
![]() the meters do not over estamate actinic, the under estimate actinic and overestimate the higher end. in a rounded out bulb this will all work out in the pudding (6500K ish) but in a actinic bulb it will give you a lower reeding than you should have and in a 3000K bulb it will give you a higher reeding than you should have. reasons are due to the spectral responce of the meters to the wave lengths, and to get a unit that reeds good all over you need to spend over 1000.00 bucks. anyways sorry if there was any confusion Mr Canadian. Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#5
|
|||||
|
|||||
![]() Thanks for the correction Steve. That makes a lot more sense now.
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" Last edited by Canadian; 04-02-2009 at 05:20 AM. |
#6
|
|||||
|
|||||
![]() Quote:
![]() Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#7
|
|||||
|
|||||
![]() Quote:
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#8
|
|||||
|
|||||
![]() Quote:
![]() |