Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Product Review and Equipment Forum

Reply
 
Thread Tools Display Modes
  #1  
Old 01-08-2009, 04:56 PM
fencer's Avatar
fencer fencer is offline
Member
 
Join Date: Aug 2007
Location: Ed Ab
Posts: 1,331
fencer is on a distinguished road
Default

A check valve for a 20 psi application should not have more than 2 psi lift value. You want to open the valve easily but you want it slam shut easily too. and seat properly. Maybe the Dennerle is all teflon(including the spring). But really any type of check valve should work
Reply With Quote
  #2  
Old 01-08-2009, 05:06 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Definitely getting into details over my head now. All I know if I blowed as bloody hard as I possibly could into it and could not get it to, er, pun-not-intended, pass air. But put it on the CO2 line and the CO2 would pass no problem (even at really low psi settings, although I still have to run mine at 18-20psi just to produce a consistent bubble rate). So, that, and the fact that it's still working four years later. I was going through those clear plastic check valves like crazy. Not that they're expensive but it's just annoying when they stop working and you have to replace them.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #3  
Old 01-08-2009, 05:54 PM
fencer's Avatar
fencer fencer is offline
Member
 
Join Date: Aug 2007
Location: Ed Ab
Posts: 1,331
fencer is on a distinguished road
Default

The reason for the difference in the lift value is because most lift check applications involve pumps. Sometimes pumps need some large backpressure to operate efficently. In passive applications a 1 or 2 psi lift is it. The most important point in check valves is how well it seats back to prevent backflow. Tony i suspect yours spring loaded poppet and the cheaper ones are a flappper type.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:14 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.