#1
|
|||||
|
|||||
![]() I'm aware of the calfo overflow design and I've used it before but didn't see the results of better surface skimming. Increasing the linear distance doesn't increase velocity, how could it since you're increase the area, so how can it increase surface skimming? The link doesn't provide any real information on larger overflows, it seems to be based more on a silent standpipe design.
Last edited by sphelps; 12-18-2008 at 02:19 AM. |
#2
|
|||||
|
|||||
![]() It doesn't increase the velocity of water flowing over the overflow, it increases the velocity at which surface-bound proteins are removed because only the surface water travels over the overflow instead of half of the flowing water coming from below the surface.
There's a rather succinct example in the link I provided: Quote:
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#3
|
|||||
|
|||||
![]() Quote:
Your theory is sound but I don't think the biggest overflow is necessarily the best. If the overflow is too big for the water flow insufficient surface tension could result. I've seen this before. The way I see it is the second overflow is not needed so why waist the space? |
#4
|
|||||
|
|||||
![]() I think if I understand it correctly ( which I probably don't ) Canadian is saying that a smaller over flow will act as a siphon of sorts and pull water not only from the surface but from further down in the water column depending on the speed of the plumbing and return pump?
That probably makes no sense....
__________________
Robb |
#5
|
|||||
|
|||||
![]() Quote:
|
#6
|
|||||
|
|||||
![]() From a practical standpoint in an aquarium I don't see it being feasible to create an overflow that it is so large that it creates insufficient surface tension at the typical flow rates used in aquariums with typical dimensions. I do however see overflows that are too small resulting in the majority of the water being drawn in from beneath the surface. You'd need to have a ridiculously long overflow at an incredibly low flow rate.
As a real world example: the overflow in my AIO is 4" long with a flow rate of around 225 GPH. A 3" overflow is adequate to handle that flow rate but even at 4" the surface of the water is around 3/8" above the overflow. The "velocity" of flow is great enough that it "draws" things towards it but the majority of the actual water flowing over the overflow is coming from beneath the water's surface and is therefore woefully inefficient. If I adjust the flow so that I don't get any surface agitation I can see the dust and organics accumulating on the water surface and how little of it is actually drawn over the overflow.
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#7
|
|||||
|
|||||
![]() Quote:
In the end I guess we have to all do whatever makes the most sense to us. But I would have to disagree and say it's much easier to make an overflow to big than too small. Worst case if the overflow is a little small you'll bring in some more water from below the surface, this doesn't sound like a bad effect as the increased surface tension will still skim the surface efficiently, if the overflow is too big for the flow rate you don't get good surface skim, it's right there in your own example. |
#8
|
|||||
|
|||||
![]() I am going to side with Canadian on this one, a single overflow will be more efficient, but in the design above it won't. for a single overflow to outperform two it has to be larger, this is why the coast to coast works so good. I would recommend going with one large one in the middle, maybe 24" wide by 3" deep. or how ever deep enough you need to get your bulkheads in. If you can go even wider.
Also we shoot ourselves in the foot when we make overflows because we put teeth in them. this allows water flow from below the surface to enter the overflow. My last tank I think I did about 5 different overflow designs over the years and the one I was most happy with was an acrylic overflow box with no teeth, just a smoothed out rounded edge. this combined with a large linear distance will cause a very thin film of water to flow over the edge. I think in my 94 I had 1500gph overflowing at a water thickness of less than 1 mm. Steve
__________________
![]() Some strive to be perfect.... I just strive. Last edited by StirCrazy; 12-18-2008 at 02:29 PM. |
#9
|
|||||
|
|||||
![]() I guess we could all agree that there is more then one way to do things, I just have to sit down go over all of my options and come to a decision on what works best for my situation.
I don't have much room behind the tank so the less pluming I have to go over top the better. There was a screw up when the cabinetry was installed and the tank ended up being 4" closer to the wall then I wanted. I'm not sure a center over flow would work. I believe the bracing on my stand might get in the way, and to modify the stand I need to remove the countertops, crown & riser , hutches plus a stub wall in the basement to get the stand out to the garage. I'm not grinding and welding in the basement! Ahh screw it, where's my 10 galon tank I'll set that up! ![]()
__________________
Robb |
#10
|
|||||
|
|||||
![]() Quote:
Quote:
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" Last edited by Canadian; 12-18-2008 at 02:29 PM. |