#11
|
|||||
|
|||||
![]() Sched 80 is so overkill for this, completely a waste. Get a normal "cheapo" and buy an extra frag with the money you saved!
__________________
Brad |
#12
|
|||||
|
|||||
![]() Well, it's comforting to know that if you ever decide to do a 20' tall columnar tank to follow your staircase from the basement to the upperfloors, what size hole you'll need for the bottom bulkheads.
![]() (I have seen tanks like this BTW .. I think it was a restaurant chain in the U.S. called "The Aquarium". ![]()
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |
#13
|
|||||
|
|||||
![]() I agree completely they are overkill, but for $22 versus $13, well worth the peace of mind after seeing the results of a failed bulkhead. Chances are it was from over tightening, but none the less, any bulkhead can fail.
__________________
28g Nano Cube drilled with 13g sump in stock stand. Vertex IN80 Skimmer, Phosban 150 Reactor, Apex Controller, DIY LED with stock hood, dimmable Established March 2006 |
#14
|
|||||
|
|||||
![]() After dealing with cracked bulkheads, both in sch40 & sch80, I will now only use Hayward Sch80s. I'd recommend the same for anyone, and I believey you can get them from Bulk Reef Supply. (they also list hole sizes for each type)
|
#15
|
|||||
|
|||||
![]() How do people crack bulkheads?? I've never personally seen one crack, either during install or afterwards. I guess to each their own, but most of my plumbing isn't even sch 40.
__________________
Brad |
#16
|
|||||
|
|||||
![]() +1 .. how exactly do you crack a bulkhead?? Are people overtightening these things ten times over?? You realize that amount of tension is bad for the glass too right? ... Hand tighten and then maybe a 1/4 turn with a wrench after that. If it's still leaking, something is wrong. If you're really paranoid, put a little silicone down. Shouldn't have to be anything more than that.
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |
#17
|
|||||
|
|||||
![]() I have a spare from my old 90 somewhere in my "extra parts bin". I remember it costing a small fortune so hopefully it is the better quality one, although I wouldn't be surprised if it was the cheapo.
__________________
Christy's Reef Blog My 180 Build Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free. |
#18
|
|||||
|
|||||
![]() if some one cracks a bulkhead that is not the fault of the bulkhead, but rather the instalation. you either tightened it way way to much , in which case your lucky the glass didn't break or you tried to force plumbing which placed a strain on the bulkhead, and again your lucky the glass didn't break.
take a look at the PSI rating for Sched 40 and let me know if you have anything on your fishtank that even comes close to 1/4 of its rating. Sched 80 is a waist of money and is bulky , cumbersome and ugly, I used sched 80 on my old tank and never will use them again if only for the physical size of area clear they need to be able to tighten them. Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#19
|
||||
|
||||
![]() 3inch hole 2inch bulkhead that means 2 inch hole in overflow i would put 1inch return from pump dont forget 1 inch check valve and 1 inch ball valve to controlyour return pressure got any ? pm me i got 2000gal running 22 tanks lots of work lol.
|
#20
|
|||||
|
|||||
![]() Quote:
![]()
__________________
I once had a Big tank...I now have two Huskies and a coyote |