Quote:
Originally Posted by asmodeus View Post
Craig its really easy to sort out here keep your plumbing the same way open your ball valve full open.
what you need to do is drill a small hole in your return pipe just above the water line in your tank. This is going to allow you to back siphon the water once it reaches the water line so make the hole just below the water line then the pump goes off the water will drain only to the pipe with the hole. SUPER EASY
This doesn't address his issue... he's trying to use the ball valve to reduce noise... Basically you want a Herbie so your gonna need 2 drains

Last edited by superduperwesman; 11-20-2008 at 03:54 PM.
Reply With Quote
  #12  
Old 11-20-2008, 03:52 PM
superduperwesman's Avatar
superduperwesman superduperwesman is offline
Member
 
Join Date: Sep 2007
Location: Calgary
Posts: 850
superduperwesman is on a distinguished road
Default

Quote:
Originally Posted by Parker View Post
I'd take the ball valve off the drain side and put it on the return side ( after the pump ) if you want to limit the flow.
Then he'll get less turnover and still have the noise issue?? The only reason his drain occasionally has problems with keeping up to the pump is because he has it restricted... and the only reason he is limiting the drain flow is for noise and bubbles not because he wants less actual flow to the tank

Last edited by superduperwesman; 11-20-2008 at 03:56 PM.
Reply With Quote
  #13  
Old 11-20-2008, 04:11 PM
Myka's Avatar
Myka Myka is offline
Moderator
 
Join Date: Mar 2004
Location: Saskatoon, SK.
Posts: 11,268
Myka will become famous soon enough
Default

Quote:
Originally Posted by cwickham View Post
hey

i use ball-valves to limit the return from my main tank to the sump. I adjust the level of the tank so that the return is completely under water to reduce micro bubbles and noise.

The problem is that if the power goes out and the tank level drops, air gets into those pipes and when the power comes back on, the air gets trapped at the ball-valve and limits the flow even more cause my tank to overflow if im not there to release the air.

is there any way around this, is there somthing that will shut my return pump off when the water gets to a certain level(just for emergency if im not home)

i have tryed to find a normally open float switch to make somthing, but can only find normally closed ones.

thanks for your help
craig

I haven't read this entire thread, so if it hasn't been mentioned yet, check out the Herbie style overflow, and see if you can mod yours like that.
__________________
~ Mindy

SPS fanatic.

Reply With Quote
  #14  
Old 11-20-2008, 04:20 PM
Parker's Avatar
Parker Parker is offline
Member
 
Join Date: Aug 2005
Location: Edmonton
Posts: 1,012
Parker is on a distinguished road
Default

Quote:
Originally Posted by superduperwesman View Post
The he'll get less turnover and still have the noise issue??

IF he is running his return pump wide open at the moment that's all the flow he will ever get out of that pump. If the drain is noisy that's a seperate issue that's needs to be addressed by a solution other then placing a valve on the drain.

Running a valve on the drain is a very dangerous way to regulate flow or noise, snail goes down his drain = flood, valves starts to gather crap, clumps of algae = flood, fish goes down the drain = flood, and it will happen eventually. It's always best to regulate flow on the return side.
__________________
Robb
Reply With Quote
  #15  
Old 11-20-2008, 04:22 PM
phillybean phillybean is offline
Member
 
Join Date: Nov 2006
Location: Kelowna
Posts: 270
phillybean is on a distinguished road
Default

Why not put a strainer on the intake side to prevent anything big from getting in the pipe?

On mine, I have a valve but leave it open. I have a strainer to prevent anything large from getting in it.

As an added precaution my overflow box / return pump section are small enough that there is no way for my tank to flood.
Reply With Quote
  #16  
Old 11-20-2008, 04:23 PM
superduperwesman's Avatar
superduperwesman superduperwesman is offline
Member
 
Join Date: Sep 2007
Location: Calgary
Posts: 850
superduperwesman is on a distinguished road
Default

Quote:
Originally Posted by Parker View Post
IF he is running his return pump wide open at the moment that's all the flow he will ever get out of that pump. If the drain is noisy that's a seperate issue that's needs to be addressed by a solution other then placing a valve on the drain.

Running a valve on the drain is a very dangerous way to regulate flow or noise, snail goes down his drain = flood, valves starts to gather crap, clumps of algae = flood, fish goes down the drain = flood, and it will happen eventually. It's always best to regulate flow on the return side.
ahah that's exactly why I said he was crazy in the first post... UNLESS you have a back up drain. I don't think he's try to "regulate flow" to the tank he just trying to reduce noise and bubbles like he mentioned in his first post which is why he is trying to control the out flow to reduce the air in the line which is why he needs a herbie style drain

He could try a few other methods... but the ball valve would seem to indicate that he's leaning toward a herbie?? Which is the quietest
Reply With Quote
  #17  
Old 11-20-2008, 04:30 PM
superduperwesman's Avatar
superduperwesman superduperwesman is offline
Member
 
Join Date: Sep 2007
Location: Calgary
Posts: 850
superduperwesman is on a distinguished road
Default

Quote:
Originally Posted by phillybean View Post
Why not put a strainer on the intake side to prevent anything big from getting in the pipe?
I think you can still get a slim build up after some time that will change the outflow enough to slowly overflow your tank even if you had it adjusted perfectly to begin with
Reply With Quote
  #18  
Old 11-22-2008, 05:58 AM
untamed's Avatar
untamed untamed is offline
Member
 
Join Date: Feb 2005
Location: Coquitlam
Posts: 2,248
untamed is on a distinguished road
Default

Quote:
Originally Posted by cwickham View Post
that would work, but id like to keep the same amount of flow, just reduce how fast it flows from the main tank to the sump
That's impossible. Water always flows to the sump at the same rate it is pumped out of the sump. If something prevents this from happening, you have overflow.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies

My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436
Reply With Quote
  #19  
Old 11-22-2008, 07:13 AM
cwickham cwickham is offline
Member
 
Join Date: Mar 2008
Location: Vancouver
Posts: 111
cwickham is on a distinguished road
Default

Quote:
Originally Posted by untamed View Post
That's impossible. Water always flows to the sump at the same rate it is pumped out of the sump. If something prevents this from happening, you have overflow.

water doesnt have to flow back into the tank as fast as its pumped up, you can restrict it to find a good balance between over flow and the perfect level.



I agree with all of you that restricting the overflow is a dangerous game, and eventaully will get clogged. I think im just going to build an electronic shut off. water gets to high for any reason, pump turns off, water drains out pump turns back on. Probably be the easyiest solution.

thanks for all your comments
Reply With Quote
  #20  
Old 11-22-2008, 02:30 PM
Canadian's Avatar
Canadian Canadian is offline
Member
 
Join Date: Oct 2001
Location: Victoria, BC
Posts: 619
Canadian is on a distinguished road
Default

Quote:
Originally Posted by cwickham View Post
water doesnt have to flow back into the tank as fast as its pumped up, you can restrict it to find a good balance between over flow and the perfect level.
For all intents and purposes it does (have to flow from the display tank at the same rate it is pumped to it by the return pump). If it didn't you'd either slowly (or quickly depending upon the disparity) overfill the display tank --> too much water in the display tank --> wet floor.

The most efficient and economical solution is to add another emergency drain line a la the Herbie method.
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets

"Mens sana in corpore sano"
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:07 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.