#1
|
|||||
|
|||||
![]() Looks like I could try it one of 2 ways.
First I could put a piece of 1/4" hose on the top, but how do you attach 1/4" hose to a piece of 1 1/2" PVC pipe so that it is adjustable? This sounds like it could be the simplest cure. Secondly I could turn my 1 1/2" drain into a "Herbie" with a gate valve and use one of the return holes for the emergency drain, leaving me with one hole for returns. The tank currently has 1 - 2 3/4" hole for 1 1/2" drain and 2 - 1 3/4" holes for 1" returns. I'm not sure I understand why one needs an emergency drain for the Herbie style, but not for the Durso. Oh my, sometimes I wonder why I started this? (Just silently venting)
__________________
![]() 10 Gal Nano Contest: http://www.canreef.com/vbulletin/sho...d=1#post348308 90 Gal Corner Pentagon Build: http://www.canreef.com/vbulletin/showthread.php?t=42263 |
#2
|
|||||
|
|||||
![]() Quote:
Your thought for using the smaller hole for the second drain is feasible only if it can handle the entire flow from the primary when it is turned off. Good luck! This can get complicated, but you'll get there. |