Old 11-14-2008, 03:59 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

the rising and lowering in the overflow indicates that the Durso is not tuned and would be getting some surging of air.

The negative with the Durso though is you'll always get air in the line back to the sump (not with a Herbie).
Reply With Quote
  #2  
Old 11-14-2008, 04:12 AM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

The first thing I would try is a 2" standpipe. It'll be the quickest and easiest fix and give a better idea where the problem lies.
Another idea would be to install a Tee directly below the bulkhead and run the branch line up and then down into another section in the sump. Next install a valve just above the sump on the main drain line. Closing the valve will cause the drain to fill with water stopping air from entering the sump. You'll want to adjust the valve so water just starts to trickle out the other drain and the back up the valve a tiny bit. This will work similar to a herbie overflow but only needs one drain, it won't be as quiet as you'll get noise through the second drain line as it's connected to the main but you should be able to muffle it.
Reply With Quote
  #3  
Old 11-14-2008, 04:28 AM
rocketlily's Avatar
rocketlily rocketlily is offline
Member
 
Join Date: Dec 2007
Location: Sherwood Park
Posts: 568
rocketlily is on a distinguished road
Default

Thanks for all your ideas. I'll try some of them out this weekend.
Reply With Quote
  #4  
Old 11-14-2008, 04:54 AM
Marlin65's Avatar
Marlin65 Marlin65 is offline
Member
 
Join Date: Jan 2008
Location: New Westminster
Posts: 1,024
Marlin65 is on a distinguished road
Default

My tank makes a huge amount of noise but if I tune it just right there is no noise. I have a 1-1/2" pipe with a basket. The thing though is I have a piece of airline zapstraped to that and just adjust it up or down to make the noise stop. If for some reason the hose clogs. (I keep it at the max height I want the tank to ever be) then the water gets sucked right down fast with tons of noise alerting me that there is a problem.
Hope that makes sense.
Maybe a small piece of hose is all you need.
__________________
150 Gal system 3'x3' 400W M/H, Bekett skimmer, Dart return,1/4 HP Chiller
180 Gal Drop tank, LED lights, Bubble master 250 skimmer,Hammerhead on a closed loop, Speed wave return.
Reply With Quote
  #5  
Old 11-14-2008, 05:05 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

sphelps, didn't you have a drawing of that and if so could you post it up again
Reply With Quote
  #6  
Old 11-14-2008, 05:56 AM
superduperwesman's Avatar
superduperwesman superduperwesman is offline
Member
 
Join Date: Sep 2007
Location: Calgary
Posts: 850
superduperwesman is on a distinguished road
Default

Quote:
Originally Posted by mark View Post
sphelps, didn't you have a drawing of that and if so could you post it up again
I think he means something like this??

Reply With Quote
  #7  
Old 11-14-2008, 01:10 PM
rocketlily's Avatar
rocketlily rocketlily is offline
Member
 
Join Date: Dec 2007
Location: Sherwood Park
Posts: 568
rocketlily is on a distinguished road
Default

Looks like I could try it one of 2 ways.

First I could put a piece of 1/4" hose on the top, but how do you attach 1/4" hose to a piece of 1 1/2" PVC pipe so that it is adjustable? This sounds like it could be the simplest cure.

Secondly I could turn my 1 1/2" drain into a "Herbie" with a gate valve and use one of the return holes for the emergency drain, leaving me with one hole for returns. The tank currently has 1 - 2 3/4" hole for 1 1/2" drain and 2 - 1 3/4" holes for 1" returns.

I'm not sure I understand why one needs an emergency drain for the Herbie style, but not for the Durso.

Oh my, sometimes I wonder why I started this? (Just silently venting)
Reply With Quote
  #8  
Old 11-14-2008, 01:39 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by superduperwesman View Post
I think he means something like this??

You got her, nice!
Reply With Quote
  #9  
Old 11-14-2008, 02:46 PM
rocketlily's Avatar
rocketlily rocketlily is offline
Member
 
Join Date: Dec 2007
Location: Sherwood Park
Posts: 568
rocketlily is on a distinguished road
Default

Quote:
Originally Posted by superduperwesman View Post
I think he means something like this??

Sorry, but can someone put some words to this picture for me.
Reply With Quote
  #10  
Old 11-14-2008, 05:39 AM
Marlin65's Avatar
Marlin65 Marlin65 is offline
Member
 
Join Date: Jan 2008
Location: New Westminster
Posts: 1,024
Marlin65 is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
The first thing I would try is a 2" standpipe. It'll be the quickest and easiest fix and give a better idea where the problem lies.
Another idea would be to install a Tee directly below the bulkhead and run the branch line up and then down into another section in the sump. Next install a valve just above the sump on the main drain line. Closing the valve will cause the drain to fill with water stopping air from entering the sump. You'll want to adjust the valve so water just starts to trickle out the other drain and the back up the valve a tiny bit. This will work similar to a herbie overflow but only needs one drain, it won't be as quiet as you'll get noise through the second drain line as it's connected to the main but you should be able to muffle it.
Great idea I would try this on mine but I don't have enough room for that now.
__________________
150 Gal system 3'x3' 400W M/H, Bekett skimmer, Dart return,1/4 HP Chiller
180 Gal Drop tank, LED lights, Bubble master 250 skimmer,Hammerhead on a closed loop, Speed wave return.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 10:28 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.